 CaUTIon: Combustion air inlet ducts shall 
not terminate in attic space.
The  maximum  height  for  the  air  vent  can  not 
exceed 3 feet below the flue gas outlet of the 
termination.
FaCToRY BUIlT CHIMneY sYsTeMs
The Grand Meridian is designed to be installed with 
1) 
FMI PRODUCTS, LLC Metal Chimney System.
This  Grand  Meridian  fireplace  is  intended  as  a 
2) 
supplemental heat source only. It is not intended 
as a primary heat source.
It  is  the  responsibility  of  the  contractor/installer 
3) 
(not  the  manufacturer)  to  ensure  that  adequate 
combustion air is provided for proper function of 
this fireplace. Fireplaces take up a large volume of 
replacement air from outside the house and if the 
house  is  of  airtight  construction,  smoke  spillage 
may occur if proper draft is not achieved.
There  are  many  conditions  beyond  the 
4) 
manufacturer’s control regarding improper fireplace 
operation.  The  manufacturer  cannot  ensure 
“smoke free” operation, nor can the manufacturer 
take  on  the  responsibility  for  problems  with 
surrounding construction; chimneys that have not 
venting installation
Figure 13 - Outside Air Kit Venting
Secure to Collars with Metal Tape, Screws 
or Straps (Min. of 1/4" x 20" in size)
Air Inlet 
Location 
Must 
Allow For 
Bushes 
or Snow
Vent Hood 
Required 
for Wall 
Installation
Vented Crawl 
Space (Check 
Local Codes 
Before Installing 
in a Vented 
Crawl Space)
oPTIonal oUTsIde aIR KIT (Model MM4aK)
The  Grand  Meridian  Fireplace  needs  enough  re-
placement  air  to  function  properly  and  some  local 
building  codes  may  require  outside  combustion  air 
to  be  provided.  If  no  replacement  air  is  provided, 
improper flue drafting may occur, creating negative 
pressure whereby smoke may enter the home, es-
pecially  in  homes  that  are  very  well  insulated  and 
tightly sealed. Check local building codes for specific 
requirements.
The installation of an outside air kit should be per-
formed during the rough framing of the fireplace due 
to the nature of it's location. Outside combustion air 
is accessed through a vented crawl space or through 
a sidewall (Figure 13). If crawl space is used, check 
local codes for proper termination.
Be sure that you carefully  check the source of the 
outside air before you choose the site for your air in-
take. You don’t want a place where snow will collect, 
where bushes or trees will be growing or a location 
that is too close to any other structure.
Install Combustion Air Kit into the firebox through the 
side wall opening provided. A 4" dia. hole will also be 
required through the firebrick side lining (see Figure 
12). The tubing that goes out of the firebox wall must 
feed into a flexible metal conduit as the source for 
outside combustible air. Install a screened termina-
tion cap to keep out small animals.
Figure 12 - Outside Air Kit Installation