Chauvet DMX512 Manuel D’Utilisation

Page de 12
LED Mushroom User Manual 
Rev. 4 
Often, the setup for Master-Slave 
and Standalone operation requires 
that the first fixture in the chain be 
initialized for this purpose via either 
settings in the control panel or DIP-
switches. Secondarily, the fixtures 
that follow may also require a slave 
setting. Please consult the 
“Operating Instructions” section in 
this manual for complete 
instructions for this type of setup 
and configuration. 
Master 
Slave 
Slave 
The fuse is located 
inside this 
compartment. 
Remove using a flat 
head screwdriver. 
3.
 
S
ETUP
 
Fuse Replacement 
With a flat-head screwdriver wedge the fuse 
holder out of its housing. Remove the damaged 
fuse from its holder and replace with exact 
same type fuse. Insert the fuse holder back in 
its place and reconnect power.  
Data Linking 
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller 
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The 
combined number of channels required by all the fixtures on a serial data link determines the number 
of fixtures the data link can support.  
Important:  
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 
standard no more than 32 devices should be connected on one data link. Connecting more than 32 
fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in 
deterioration of the digital DMX signal.  
Maximum recommended serial data link distance: 500 meters (1640 ft.) 
Maximum recommended number of fixtures on a serial data link: 32 fixtures 
Data Cabling 
To link fixtures together you must obtain data cables. You can purchase CHAUVET®-certified DMX 
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 
cable please use data-grade cables that can carry a high quality signal and are less prone to 
electromagnetic interference. If you are unfamiliar with DMX, download the DMX Primer from 
CAUTION 
Do not allow contact between the common and the fixture’s chassis ground. Grounding the common 
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to 
verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. 
Master/Slave Linking 
1.  Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector 
of the first fixture. 
2.  Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, 
proceed to connect from the output as stated above to the input of the following fixture and so on. 
 
 
 
 
 
Disconnect the power cord before replacing a fuse and always 
replace with the same type fuse.