Lennox elite vint-dvs-u Manuel D’Utilisation

Page de 32
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Alcove
Option 1
Alcove
Option 3
Alcove
Option 2
Carpet
Leg
1-1/2” (38mm)
Maximum
Corner Installation
Clearances to Combustibles
Minimum clearances to combustible materials shown here are in inches 
(millimeters).  See Pages 8 and 9 for pipe clearances.
Floor Protection
A non­combustible hearth pad is not required. This stove may be installed 
on a combustible surface as long as the combustible material (such as 
carpeting) does not extend 1­1/2” vertically above the bottom of the legs 
(see Figure 6). Also, the floor beneath the stove must be stable, level, hard 
and strong enough to support the stove without a tipping hazard.
Leg on Combustible
90
˚
4"
(102mm)
10-5/8"
(270mm)
13-7/8"
(352mm)
4"
(102mm)
Co
mb
ust
ible
 Wa
ll
Com
busti
ble W
all
4"
(102mm)
15-1/4"
(387mm)
4"
(102mm)
Co
m
bu
sti
ble
 W
all
Combustible Wall
Figure 4
Figure 5
Figure 6
Alcove dimensions
The minimum width between alcove side walls is 30­1/2” (775mm). The 
glass door lifts up to access the firebox on the stove. Therefore, if the stove 
is to be installed in an alcove, the alcove needs to be constructed to allow 
for removal of the glass door. Option 1:  The maximum alcove depth is 
15” (381mm) (maintaining a 4” [102mm] rear clearance the stove will be 
positioned partly into the room) and the remaining minimum dimensions 
to combustibles are as shown in the Option 1 drawing below. Option 2:  
The alcove is 43” (1092mm) high to provide sufficient space to remove 
the door. The maximum depth of the alcove is 24” (610mm). Option 3:  
Should an alcove depth from 2 feet (.61M) to 4 feet (1.22M)be desired 
then the minimum alcove height is 54” (1372mm). Access to the stove’s 
controls should be considered when determining the alcove size.
33”
838mm
  15”
381mm
40”
1016mm
42”
1067mm
30-1/2”
775mm
43”
1092mm
24”
    610mm
30-1/2”
775mm
30-1/2”
775mm
54”
1372mm
48”
    1219mm
Figure 7
Figure 8
Figure 9
Parallel Installation