3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
These appliances comply with National Safety 
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-31-5) to 
ANSI ZZ21.88b-2003 (in Canada, CSA-2.33b-
2003), and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas fi replace heaters.
The Installation must conform to local codes 
or, in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
54-latest edition, or the Natural Gas and 
Propane Installation Code, CSA B149.1-latest 
edition.  The appliance, when installed, must 
be electrically grounded in accordance with 
local codes or, in the absence of local codes, 
the latest edition of the National Electrical Code, 
ANSI/NFPA 70, or the Canadian Electrical Code, 
CSA C22.1 - latest editions.
GENERAL INFORMATION
Note:  Installation and repair should be per-
formed by a qualifi ed service person. The 
appliance should be inspected annually by a 
qualifi ed professional service technician. More 
frequent inspections and cleanings may be 
required due to excessive lint from carpeting, 
bedding material, etc.
It is imperative that the control compartment, 
burners and circulating air passage ways of  
appliance be kept clean.  See Maintenance 
instructions on Page 6.
S'assurer que le brùleur et le compartiment des 
commandes sont propres.  Voir les instructions 
d'installation et d'utilisation qui accompagnent 
l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front openings of the appliance.
Due to high temperatures the appliance should 
be located out of traffi c and away from furniture 
and draperies.  Locate furniture and window 
coverings accordingly.
These fi replaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have 
an alternate heat source when installed in a 
dwelling.
 Input (BTU) MAnnually-Modulated Gas 
Valves (millivolt models)
NATURAL GAS
Models
Input Rate
(BTU/HR)
LMDVT-3328CNM
LMDVR-3328CNM
17,500 high
11,700 low
LMDV-3530CNM
20,000 high
12,800 low
LMDV-4035CNM
27,000 high
18,500 low
Table 1
 Input (BTU) MAnnually-Modulated Gas 
Valves (millivolt models)
PROPANE GAS
Models
Input Rate
(BTU/HR)
LMDVT-3328CPM
LMDVR-3328CPM
17,500 high
14,000 low
LMDV-3530CPM
20,000 high
15,200 low
LMDV-4035CPM
27,000 high
21,500 low
Table 2
Input (BTU) - Fixed Rate
(electronic models)
NATURAL GAS & PROPANE GAS
Models
Input Rate
(BTU/HR)
LMDVT-3328CNE
LMDVR-3328CNE
17,500
LMDV-3530CNE
20,000 
LMDV-4035CNM
LMDV-4035CPM
28,000 
Table 3
TABLE OF CONTENTS
Safety & Warning Information ..........Page  2
Introduction ......................................Page  3
General Information ..........................Page  3
Gas Controls Access .........................Page  4
Operation/Care of Your Appliance .....Page  4
Variable Flame Adjustment ................Page  5
Maintenance ......................................Page 
6
Front Glass Enclosure Panel,
  Removal and Installation .................Page  6
Install Vermiculite, Volcanic Stone,
Embers & Logs .................................Page  8
Burner Flame Appearance & Sooting Page  11
Burner Flame Adjustments ................Page  12
Millivolt Appliance Checkout .............Page  12
Electronic Appliance Checkout ..........Page  12
Wiring Diagrams ...............................Page  13
Warranty ...........................................Page  13
Product Reference Information .........Page  13
Accessory Components ....................Page  14
Lighting Instructions – Millivolt ........Page  18
Lighting Instructions – Electronic .....Page  20
Maintenance Schedule ......................Page  22
Troubleshooting Guide – Millivolt .....Page  23
Troubleshooting Guide – Electronic ..Page  23
Replacement Parts List .....................Page  25
CONGRATULATIONS!
In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the fi nest and most 
dependable fi replace to be found anywhere.  Its a beautiful, prestigious alternative to a 
wood burning fi replace.  Welcome to a Family of tens of thousands of satisfi ed LENNOX 
Fireplace Owners.
Please carefully read and follow all of the instructions found in this manual.  Please pay 
special attention to the safety instructions provided in this manual.  The Homeowner's 
Care and Operation Instructions included here will assure that you have many years of 
dependable and enjoyable service from your LENNOX product.
INTRODUCTION
The Fireplace models covered in this manual 
are Direct-Vent sealed combustion gas fi replace 
heaters designed for residential application.  
Direct-Vent appliances operate with the com-
bustion chamber completely isolated from the 
indoor environment.  All air for combustion is 
brought in from the outside and  exhaust gases 
are vented through the same direct vent, co-axial 
(intake/exhaust) vent system.
The Millivolt appliances have a millivolt gas 
control valve with piezo ignition system provides 
safe, effi cient operation. If any optional acces-
sories which require electrical power are being 
installed, the electrical power must be provided 
at the time of appliance installation.
The Electronic appliances have an electronic 
intermittent pilot system provides safe, effi cient 
operation. External electrical power is required 
to operate these appliances.
These appliances are designed to operate on natural 
gas or propane gas only. The use of other fuels or 
combination of fuels will degrade the performance 
of this system and may be dangerous.
Millivolt Models - BTU Input
Millivolt  models come standard with the mAnnu-
ally-modulated gas valve; fl ame appearance and 
heat output can be controlled at the gas valve. 
The BTU Input for millivolt models is shown in 
Tables 1 & 2:
Electronic Models - 
Electronic models have a fi xed rate gas valve.
The BTU Input for electronic models is shown 
in Table 3: