National Instruments SCXI-1121 Manuel D’Utilisation

Page de 162
Appendix E
SCXI-1121 Cabling
© National Instruments Corporation
E-11
6.
Snap the cover back in place.
7.
Reinsert the rear grounding screw. The terminal block is now ready to 
be connected to the front panel connector.
Figure E-4.  Cover Removal
SCXI-1302 Installation 
Follow these steps to install the SCXI-1302:
1.
Install an SCXI-1180 feedthrough panel as described in the SCXI-1180 
Installation
 section.
2.
Wire the terminal block as described in the SCXI-1302 Wiring 
Procedure
 section.
3.
Connect the SCXI-1302 terminal block to the front panel connector on 
the SCXI-1180 feedthrough panel. Be careful to fit the thumbscrews in 
the thumbscrew cutouts.
4.
Tighten the top and bottom captive screws on the back of the terminal 
block into the screw holes in the front panel. This will hold the 
SCXI-1302 securely in place.
5.
Check the installation.
50-Pin 
Connector
Grounding 
Screw
Thumbscrew Cutout
Step 1
Step 2
Insert Screwdriver in 
Groove and Rotate to 
Pry Open