Vulcan Materials c24ea3 Manuel D’Utilisation
— 7 —
C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING
CONNECTIONS MUST COMPLY
WITH APPLICABLE PORTIONS
OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WITH APPLICABLE PORTIONS
OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
The wiring diagram is located on the right side
panel as you face the steamer. This steamer is
hard wired.
panel as you face the steamer. This steamer is
hard wired.
Total
Volts
Hz
Ph
KW Per Phase
Rated Amps
Circuit
Fuse
90°C
KW
3-Phase Amps Per Line
Single
Size
Size
Copper
L1-L2
L2-L3
L3-L1
L1
L2
L3
Phase Amps
or
Min.
Circuit
Wire
Breaker
Size
Size*
(Amps)
8.5
208
50/60
1
40.87
60
60
8
8.5
240
50/60
1
35.42
50
50
8
8.5
208
50/60
3
4.25
2.12
2.12
26.54
26.54
17.70
35
35
10
8.5
240
50/60
3
2.83
2.83
2.83
20.50
20.50
20.50
30
25
10
8.5
480
50/60
3
2.83
2.83
2.83
10.30
10.30
10.30
15
15
16
9.25
208
50/60
1
43.57
60
60
6
9.25
240
50/60
1
38.54
50
50
8
9.25
208
50/60
3
4.25
2.69
2.12
26.54
28.88
20.04
35
35
10
9.25
240
50/60
3
2.83
3.58
2.83
20.45
23.15
23.15
30
30
10
9.25
480
50/60
3
2.83
3.58
2.83
10.21
11.57
11.57
15
15
16
15
208
50/60
1
72.12
90
90
4
15
240
50/60
1
62.50
75
75
6
15
208
50/60
3
7.50
3.75
3.75
46.84
46.84
31.23
60
60
6
15
240
50/60
3
5.00
5.00
5.00
36.08
36.08
36.08
50
50
8
15
480
50/60
3
5.00
5.00
5.00
18.04
18.04
18.04
25
25
14
15.75
208
50/60
1
74.82
90
90
4
15.75
240
50/60
1
65.63
80
80
4
15.75
208
50/60
3
7.50
4.31
3.75
46.84
49.18
33.57
60
60
6
15.75
240
50/60
3
5.00
5.75
5.00
36.08
38.79
38.79
50
50
8
15.75
480
50/60
3
5.00
5.75
5.00
18.04
19.40
19.40
25
25
14
2002 National Electric Code
*Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker
Circuit Size (minimum) & Fuse/Circuit Breaker Size (maximum) compiled in accordance with the
National Electrical Code (ANSI/NFPA 70), 2002 Edition.
National Electrical Code (ANSI/NFPA 70), 2002 Edition.