Vulcan Materials c24ea3 Manuel D’Utilisation

Page de 24
— 7 —
C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
ELECTRICAL CONNECTION
WARNING: ELECTRICAL  AND  GROUNDING
CONNECTIONS  MUST  COMPLY
WITH  APPLICABLE  PORTIONS
OF  THE  NATIONAL  ELECTRICAL
CODE  AND/OR  OTHER  LOCAL
ELECTRICAL  CODES.
The wiring diagram is located on the right side
panel as you face the steamer. This steamer is
hard wired.
Total
Volts
Hz
Ph
KW Per Phase
Rated Amps
Circuit
Fuse
90°C
KW
3-Phase Amps Per Line
Single
Size
Size
Copper
L1-L2
L2-L3
L3-L1
L1
L2
L3
Phase Amps
or
Min.
Circuit
Wire
Breaker
Size
Size*
(Amps)
8.5
208
50/60
1
40.87
60
60
8
8.5
240
50/60
1
35.42
50
50
8
8.5
208
50/60
3
4.25
2.12
2.12
26.54
26.54
17.70
35
35
10
8.5
240
50/60
3
2.83
2.83
2.83
20.50
20.50
20.50
30
25
10
8.5
480
50/60
3
2.83
2.83
2.83
10.30
10.30
10.30
15
15
16
9.25
208
50/60
1
43.57
60
60
6
9.25
240
50/60
1
38.54
50
50
8
9.25
208
50/60
3
4.25
2.69
2.12
26.54
28.88
20.04
35
35
10
9.25
240
50/60
3
2.83
3.58
2.83
20.45
23.15
23.15
30
30
10
9.25
480
50/60
3
2.83
3.58
2.83
10.21
11.57
11.57
15
15
16
15
208
50/60
1
72.12
90
90
4
15
240
50/60
1
62.50
75
75
6
15
208
50/60
3
7.50
3.75
3.75
46.84
46.84
31.23
60
60
6
15
240
50/60
3
5.00
5.00
5.00
36.08
36.08
36.08
50
50
8
15
480
50/60
3
5.00
5.00
5.00
18.04
18.04
18.04
25
25
14
15.75
208
50/60
1
74.82
90
90
4
15.75
240
50/60
1
65.63
80
80
4
15.75
208
50/60
3
7.50
4.31
3.75
46.84
49.18
33.57
60
60
6
15.75
240
50/60
3
5.00
5.75
5.00
36.08
38.79
38.79
50
50
8
15.75
480
50/60
3
5.00
5.75
5.00
18.04
19.40
19.40
25
25
14
  2002 National Electric Code
  *Dual Element Time-Delay Fuse or Inverse Time Circuit Breaker
Circuit Size (minimum) & Fuse/Circuit Breaker Size (maximum) compiled in accordance with the