Hobart HGFD45 ML-126417 Manuel D’Utilisation

Page de 36
– 26 –
Timers 
6
  through  
0
 :
1. Press  
P
  and enter the program mode. PROGRAM is displayed in the window.
2. Press  
12
6
9
3
  . The LED's on timers  
6
  through  
0
  are lit and SELECT PRODUCT is displayed
in the window.
3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the
window.
4. Enter the desired time using keys  
1
  through  
0
 . The time is displayed in the window. After
entering the time, press  
P
 ; SELECT PRODUCT is displayed in the window and the LED's
on timers  
6
  through  
0
 are lit.
5. Repeat steps 3 and 4 to program the remaining timers or press 
P
 
P
 to exit the program
completely.
Advanced Time Features
Each timer has additional timing functions that can be programmed to fit your particular operation.
• DUTY TIME -  Notifies the operator during a fry cycle to perform a particular task (shake a
basket, flip a product, etc.). When the remaining cook time is the same as the Duty Time, a
beeper sounds and DUTY # displays in the window. Press the flashing timer number to silence
the beeper. The beeper cancels after 5 seconds if not silenced.
• HOLD TIME -  Starts after the initial timer beeper is silenced; HD# XX:XX is displayed in the
window. After timing out, a beeper sounds. Press the flashing timer number to silence the
beeper. The beeper cancels after 5 seconds if not silenced.
• COMPENSATED TIME - Automatically adjusts the time for variations in load sizes.
• STRAIGHT TIME - Does not adjust time for variations; used for regular timing operations.