lift-master 1a6189 Manuel D’Utilisation

Page de 1
1 A 6 1 8 9   A U X I L L A R Y   C O N T A C T S   O P T I O N   B O A R D
To avoid SERIOUS personal INJURY or DEATH from electrocution,
DISCONNECT electrical power to operator before proceeding.
WARNING
CAUTION
WARNING
WARNING
Commercial door operator accessory for use only with LiftMaster solid state commercial door operators.
To avoid damage to relays, DO NOT exceed maximum contact rating
of 10A at 240VAC. NOT applicable for incandescent loads.
Conduit, wiring and connectors should be sized and installed per the
national electrical code.
WARNING
CAUTION
WARNING
WARNING
NOTE: Power for devices controlled by the auxillary contacts to
be supplied from an external source.
Auxillary Contacts Option Board
The Auxillary Contacts Option Board has both normally-open
and normally-closed contacts that actuate when the door is
opening, closing and when the unit is powered down.
When the operator is powered up, the following contact outputs
are available:
DEFAULT OPERATION
While opening:
open 2 - 1 closed
(Open Aux. Contact)
open 2 - 3 opened
While closing:
close 2 - 1 opened
(Closed Aux. Contact)
open 2 - 3 closed
Operator powered down:
open 2 - 1 opened
open 2 - 3 closed
close 2 - 1 closed
close 2 - 3 opened
Operator powered on and
open 2 - 1 opened
door not in motion:
open 2 - 3 closed
close 2 - 1 closed
close 2 - 3 opened
INSTALLATION
Connect wires to terminals as needed. Use copper wire only #14
AWG maximum. Plug option board into either slot at the end of
the logic board. Reconnect power to operator. The green light(s)
on the option board will turn on if the board is seated properly
and the power is on.
LEARN REMOTE TO TURN ON/OFF AND 
AUXILLARY CONTACT
Either of the auxillary contacts on the card can be programmed
to be turned on or off by use of a remote control. Either one or
both contacts may be programmed independently. This can be
used for controlling accessories such as a fan or light that is
within the voltage and operating specifications of the relay
contact. The user must release and reactivate the remote to
switch state again.The RADIO LED will remain on while a valid
command is being received.
INPUT
RESULT
DISPLAY
Press and release
Enter the RADIO
The radio LED
the radio button.
function learning mode.
will turn on solid.
Press and release the
Enter AUX. relay (A) or (B) The radio LED
MRT button on the
function learning mode.
flashes rapidly
logic board to program This depends on weather
then remains on
relay A or press and
MRT or MID SET was
solid.
release the MID SET
pressed.
button on the logic
board to program relay B.
Press and release the
The remote button will
The radio LED
remote button to be
be learned to the function. flashes rapidly and
learned.
then turns off.
Press and release the
The learning mode will be
The radio LED
radio button.
exited.
flashes rapidly
then turns off.
Auxillary Contacts
Option Board
Logic Board
Insert PCB Board
into either slot
AUX CONTACTS
C3
K1
K2
R5
C5
TB2
OPEN
CLOSE
1    2    31    2    3
1    2    3
TB1
C6
R7
R8
D2
+5V  +24V
C4
R6
D3
D4
Q2
R4
R9
Q1
R3
R1
D1
+
C7 R2
R10
C2
C1
J1
10
1
Green Lights
Terminals
© 2005, The Chamberlain Group, Inc.
01-31099
All Rights Reserved
Printed in Mexico
AUXILLARY RELAY A OR B PROGRAMMING PROCEDURE