3-7-3   Onboard Super IO Function 
CMOS Setup Utility – Copyright(C) 1984-2004 Award Software 
Onboard Super IO Function 
 
Item Help 
 
   Onboard FDD Controller         Enabled 
   Onboard Serial Port 1          3F8/IRQ4 
   Onboard Serial Port 2          Disabled 
   UART Mode Select               Normal 
   IR2 Duplex Mode                Half 
   Onboard Parallel Port          378/IRQ7 
   Parallel Mode                  SPP 
   ECP Mode Use DMA               3 
 
 
  Menu Level >> 
 
↑↓→←
 Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit  F1:General Help 
F5:Previous Values   F6:Optimized Defaults    F7:Standard Defaults 
Onboard FDD Controller 
Select Enabled if your system has a floppy disk controller (FDD) installed on the system board 
and you wish to use it.  If you install add-on FDC or the system has no floppy drive, select 
Disabled in this field.  The settings are: Enabled and Disabled. 
Onboard Serial Port 1/Port 2 
Select an address and corresponding interrupt for the first and the second serial ports.  The 
settings are: 3F8/IRQ4, 2E8/IRQ3, 3E8/IRQ4, 2F8/IRQ3, Disabled, Auto. 
UART Mode Select 
This item allows you to determine which InfraRed(IR) function of the onboard I/O chip, this 
functions uses. 
Onboard Parallel Port 
There is a built-in parallel port on the on-board Super I/O chipset that Provides Standard, ECP, 
and EPP features. It has the following option: 
Disabled 
 
(3BCH/IRQ7)/  Line Printer port 0 
(278H/IRQ5)/  
Line Printer port 2 
(378H/IRQ7)  
Line Printer port 1  
Parallel Port Mode 
SPP  
: Standard Parallel Port 
EPP  
: Enhanced Parallel Port 
ECP 
: Extended Capability Port 
SPP/EPP/ECP/ECP+EPP 
To operate the onboard parallel port as Standard Parallel Port only, choose “SPP.”  To operate the 
onboard parallel port in the EPP modes simultaneously, choose “EPP.”  By choosing “ECP”, the 
onboard parallel port will operate in ECP mode only.  Choosing “ECP+EPP” will allow the 
onboard parallel port to support both the ECP and EPP modes simultaneously.  The ECP mode 
has to use the DMA channel, so choose the onboard parallel port with the ECP feature.  After 
selecting it, the following message will appear: “ECP Mode Use DMA” at this time, the user can 
choose between DMA channels 3 to 1.  The onboard parallel port is EPP Spec. compliant, so 
after the user chooses the onboard parallel port with the EPP function, the following message will 
be displayed on the screen: “EPP Mode Select.”  At this time either EPP 1.7 spec. or EPP 1.9 
spec. can be chosen.