6.  HIGH POWER Mode
HIGH POWER mode can be used to increase the output of the 
indoor unit for all operation modes except automatic operation.
Press the HIGH POWER button while the unit is operating.
The 
 mark appears in the display. 
To cancel, press HIGH POWER button again.
• When the HIGH POWER button is pressed, the unit operates at 
maximum output for 30 minutes, regardless of the desired 
temperature. The fan speed is 1 step above “High”.
• HIGH POWER Mode cannot be used when the operation mode 
is in Automatic Operation.
• QUIET Mode and HIGH POWER Mode cannot be used at the 
same time.
• Pressing the MODE selector button cancels HIGH POWER 
mode. 
• When set to High fan speed during heating operation, the fan 
runs at High fan speed even though the 
 mark is displayed.
• Depending on the operating conditions, the fan speed may be 
increased by a small amount only.
SPECIAL REMARKS
 
How it works?
• Once the room temperature reaches the level that was set, the 
unit’s operation frequency is changed automatically.
• During DRY operation, the fan speed automatically runs at lower 
speed for providing a comfortable breeze.
• ‘‘DRY’’ operation is not possible if the indoor temperature is 15 °C 
or less.
Heating performance
• Because this air conditioner heats a room by drawing in the heat 
of the outside air (heat pump system), the heating efficiency will 
fall off when the outdoor temperature is very low. If sufficient heat 
cannot be obtained with this air conditioner, use another heating 
appliance together with it.
Defrosting
• When the outdoor temperature is low, frost or ice may form on 
the heat exchanger coil, reducing heating performance. When 
this happens, a microcomputer defrosting system operates. At 
the same time, the fan on the indoor unit stops and the 
OPERATION lamp lights red and orange alternately until 
defrosting is completed. Heating operation restarts after several 
minutes. (This interval will vary slightly depending upon the 
outdoor temperature and the way in which frost forms.)
Cold draft prevention
• For several minutes after the start of heating operation, the 
indoor fan runs at a lower speed until the indoor heat exchanger 
coil has warmed up sufficiently. However, the fan may remain 
stopped when the room temperature is low. This is because the 
COLD DRAFT PREVENTION SYSTEM is in operation.
• In the event of power failure, the unit will stop. When the power is 
resumed, the unit will restart automatically within 15 minutes by 
the remote controller.
Clicking sound is heard from the air conditioner
• In heating or cooling operation, any plastic parts may expand or 
shrink due to a sudden temperature change. In this event, a 
clicking sound may occur. This is normal, and the sound will 
soon disappear.
• The remote controller sends the setting condition to the air 
conditioner regularly at five minute intervals.
NOTE
‘‘DRY’’ ( ) Operation
Heating ( ) Operation
Power failure during operation
Clicking Sound