Panasonic KYR615AB Mode D’Emploi

Page de 168
 48 
EN
1.  Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance  
 branch circuit.
2.  Connect the power cord.
Connect the power cord in accordance with all governing codes and  
ordinances.
 
Single-phase connection (220-240 V ~ 50 Hz) 
 
Connect the wires in accordance with the instructions given in the  
 
following table and diagram:
 
Three-phase connection (380-415 V 2N~ 50 Hz) 
Separate the L wires and connect them in accordance with the 
instructions given in the following table and diagram:
Electrical cable
Wire connection
      : Yellow / Green  
(Connect to the earth terminal)
N: Grey and Blue together
L: Black and Brown together
(Connect to the live terminal)
Electrical cable
Wire connection
      :
 Yellow / Green  
(Connect to the earth terminal)
N: Grey and Blue together
L1: Black 
L2: Brown 
(Connect to the live terminal)
L1
L2
N
Electrical Work
Electrical Connections
N
L