Weed Instrument 2M61 Multiplexer Guide De Spécification

Page de 2
Safety and Warning Information 
Important  Notice  -  Before  utilizing  the  product,  the  user  should 
determine the suitability of the product for its intended use.  The 
user  assumes  all  risk  and  liability  in  connection  with  such  use.  
WEED  INSTRUMENT'S  WRITTEN  WARRANTY  FOR  THE 
PRODUCT  IS  MADE  IN  LIEU  OF  ALL  OTHER WARRANTIES, 
EXPRESSED 
OR 
IMPLIED 
WARRANTIES 
OF 
MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR 
PURPOSE.    The  user's  exclusive  remedy  for  breach  of  Weed 
Instrument's  written  warranty  shall  be  the  repair  or  replacement 
of such quantity of product which is proven to be defective.  In no 
case shall Weed Instrument be liable for any special, incidental, 
or  consequential  damages  based  upon  breach  of  contract, 
negligence, strict liability or other legal theory. 
Publication Number: 
RM0900170  Rev. 9/05 
Fiber Optics 
EOTec 2000 MUX Model 
2M61 
MUX Base Module 
Installation Instructions 
 
Optical Compatibility: 
1300nm, Single-mode Fiber 
with SC Optical Connections 
 
 
Power Requirements 
12 to 30VDC @ 400mA 
via the top-front screw 
terminal connections 
 
--OR— 
 
9VDC @ 200mA from a 
2A06 or 2A16 power 
supply via the 
interconnection bus 
 
Connections 
Pluggable, Cage Clamp 
Screw Terminal Blocks, 
Accept 12 to 24 AWG  
 
Alarm Output Relay 
Located at the lower-
front of the module 
Form-C (SPDT) rated 
1A @ 30VDC 
 
Update Rate 
57.6KHz, independent 
of number of 
modules/channels 
utilized 
 
Optical Connection 
SC 
 
Optical Fiber Type 
Single-Mode 
 
Optical Dynamic Range 29dB, over 9/125 fiber 
 
Ambient Temp. Effect  0.025% / 50°C change 
 
Ambient Conditions 
-40 to 85°C 
 
 
 
0 to 95% Humidity 
 
 
 
(Non-condensing) 
 
Mounting 
 
35mm DIN Rail 
 
Weight   
 
< 9oz 
 
Flammability Rating 
UL V-0  
 
Specifications 
Weed Instrument Co., Inc. 
 
Phone: 
800-880-9333 
 
512-434-2850
 
Fax: 
512-434-2851
 
Email: 
fiberop@weedinstrument.com
 
Visit: 
www.weedinstrument.com 
 
Connect  the  DIN  Rail,  via  the  Model  2A09  End 
Clamp,  to  protective  earth  ground  with  low 
impedance.    The  modules  are  grounded  to  PE 
when  they  are  snapped  onto  the  DIN  Rail.    A 
Model  2A09  End  Clamp  on  each  side  of  the 
module  bundle  on  the  DIN  rail  prevents 
accidental  disconnection  of  the  modules’ 
interconnection bus. 
 
 
When  in  operation,  do  not  look  directly  into  the 
transmit  optical  port  or  use  magnification  or 
focusing equipment to view optical output. 
 
IEC 60825-1, Class 1 Laser Product 
FDA 21 CFR 1040.10 & 1040.11 
 
CAUTION:  Use  of  controls  and/or  adjustments 
or  the  performance  of  procedures  other  than 
those  specified  herein  may  result  in  hazardous 
radiation exposure.