Panduit CDPP8RG Copper Patch Panel Guide De Spécification
www.panduit.com
IndustrialNet
™
8-Port DIN Rail Mount
Copper Patching Solution
8-Port DIN Rail Mount Copper
Patch Panel
8-port DIN panel: CDPP8RG
Mini-Com
®
Copper Jack Modules
Category 6,
unshielded:
CJ688TG**
Category 6,
unshielded, keyed: CJK688TG**
Category 6,
Category 6,
shielded:
CJS688TGY
Category 6,
shielded, keyed:
CJSK688TG**
Category 5e,
unshielded:
CJ5E88TG**
Category 5e,
unshielded, keyed: CJK5E88TG**
Category 5e,
Category 5e,
shielded:
CJS5E88TGY
Category 5e,
shielded, keyed:
CJSK5E88TG**
Mini-Com
®
Blank Modules
Blank modules:
CMBIG-X‡
Shielded Jack Module
Grounding Kit
Grounding Kit:
CJSGK-XY
IndustrialNet
™
Ethernet Enclosures
Pre-configured large
(3-DIN rail) zone
enclosure:
IAZ2436C
Pre-configured medium
(2-DIN rail) zone
enclosure:
IAZ2424C
Pre-configured small
(1-DIN rail) zone
enclosure:
IAZ1214C
Ultimate ID
®
Replacement Covers
2-port clear cover:
UILC2CL-X
Ultimate ID
®
Labels
2-port white,
non adhesive:
UILWOL2-L
LS8E and LS9:
UILS8BW
Laser/Ink Jet:
UILJ2
** = IW (Off White), WH (White),
IG (International Gray), AW (Arctic White),
EI (Electric Ivory), BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green),
OR (Orange), VL (Violet). Keyed jacks are not
available in all colors. See www.panduit.com
for the complete selection.
‡For other colors, replace
‡For other colors, replace
IG (International Gray) with IW (Off White),
EI (Electric Ivory), WH (White),
RG (Rock Gray), or BL (Black).
For complete copper patch cord offering,
For complete copper patch cord offering,
visit www.panduit.com
S P e C I f I C a t I o N S H e e t
a p p l i c a t i o n s
IndustrialNet
™
8-port DIN Rail Mount Patching
Solutions conserve precious real estate by
consolidating all patching onto the DIN rails
of a zone enclosure or control panel, and are
designed to “port map” to Industrial Ethernet
modular mini-switches. These products
can be deployed as flexible, reconfigurable
and high performance structured cabling
elements in traditional hierarchical star, fiber
to the enclosure (zone) or device level ring
Industrial Ethernet architectures. These
structured cabling solutions are important as
Ethernet reaches further into the industrial
automation network, enabling traditional
IT departments to manage change in the
industrial network through the use of familiar
patching facilities and structured cabling
models. The use of Panduit IndustrialNet
™
Modular Patching allows customers to easily
deploy copper connectivity in the same
modular DIN footprint in such applications.
t e c h n i c a l i n f o r m a t i o n
Standards:
Norme International Standard CEI IEC 60715; DIN EN 60715;
DIN EN 50022; DIN 46277-3; BS 5584:1978:, IEC 60068
Environmental Testing; cULus Listed to UL1863
Material:
UL94V-0, Impact-resistant polycarbonate
RoHS compliance:
Compliant
Mounting options:
Mounts to a standard 35mm DIN rail; can also mount to other
surfaces using mounting holes in latches
Packaging:
Copper patch panel includes 6-32 x 3/8" phillips head screws
to mount faceplate to patch panel and 4 labels and
label covers.
Temperature:
Temperature range of -10°C to 60°C (14°F – 140°F) complies
to UL 508 A Control Panel standard and operating range of
the ethernet switches
Shielded applications:
For use in shielded or unshielded applications; for shielded
application, use with grounding kit CJSGK-XY
k e y f e a t u r e s a n d b e n e f i t s
DIN rail mount
Employs dual purpose, snap-in mounting latches which have an
audible click to indicate the latch is in the correct position. The
latches serve to hold the unit on the DIN rail while allowing it to
slide side to side. Latches also serve as wall mounting brackets
via an external mounting hole in the latch.
Modular
Accepts up to eight single Mini-Com
®
Copper and A/V Modules.
Patching
Easy and logical port mapping to common Ethernet mini-switch
ports enables convenient MACs (Moves, Adds and Changes)
in industrial telecommunications zone enclosure or control
panel applications. IndustrialNet
™
8-port DIN Rail Mount
Patching Solutions provides a testable permanent link for link
commissioning and troubleshooting, and provides flexibility and
scalability for future growth.
Identification
DIN rail mount patching solutions include label pockets, labels,
and transparent label covers for clear identification; complies
with ANSI/EIA/TIA-606-B labeling requirements
s p e c i f i c a t i o n s
8-port DIN rail mount copper patch panel shall be made of high impact
polycarbonate material and shall mount to a standard 35mm DIN rail.
Product shall have a removable faceplate that includes four label
pockets, labels and covers for port identification. The product shall
include adjustable latches to lock it in place when mounted on the
DIN rail. Latch design shall also allow product to mount on a flat surface
for vertical bulkhead mounting. 8-port DIN rail mount patch panel shall
accept any Mini-Com
®
Module that occupies a single space. The
panel shall be suitable for use in shielded or unshielded applications.
^