Panduit PUR6C04BU-U CAT 6 Cable Guide De Spécification
Electrical performance: Certified channel performance in a 4-connector configuration up to
100 meters and meets ANSI/TIA-568-C.2 Category 6
standard at swept frequencies up to 250MHz
Certified component performance up to 100 meters and meets the
component requirements of ANSI/TIA-568-C.2 Category 6 component
standard at swept frequencies up to 250 MHz
Conductors/insulators: Plenum – 23 AWG solid copper covered by FEP/polyolefin insulation
Riser – 23 AWG solid copper covered by polyolefin insulation
Flame rating:
Plenum – NFPA 262
Riser – UL1666
PoE compliance:
Meets IEEE 802.3af and IEEE 802.3at for PoE applications
Installation tension:
25 lbf (110N) maximum
Temperature rating:
32°F to 122°F (0°C to 50°C) during installation
-4°F to 167°F (-20°C to 75°C) during operation (Riser)
-4°F to 167°F (-20°C to 75°C) during operation (Plenum)
Cable jacket:
Plenum – low smoke, flame-retardant PVC
Riser – flame-retardant PVC
Cable diameter:
Plenum – 0.224 in. (5.7mm) nominal
Riser – 0.210 in. (5.3mm) nominal
Cable weight:
Plenum – 29 lbs./1000 ft. (13 kg/305m)
Riser – 22 lbs./1000 ft. (10 kg/305m)
Packaging:
1000 ft. (305m) in an easy payout carton
Package tested to ISTA Procedure1A
TX6
™
Category 6 U/UTP Copper Cable
S P E C I F I C A T I O N S H E E T
www.panduit.com
Cable Prep Tools
Wire snipping
tool:
CWST
Wire stripping
tool: CJAST
*For standard cable colors, add suffix BU
(Blue), WH (White), RD (Red), OR (Orange),
YL (Yellow), GR (Green), VL (Violet), IG
(International Gray), or BL (Black). Cable avail-
able in a standard pallet configuration of 36 car-
tons per pallet.
For other colors or pallet configurations,
For other colors or pallet configurations,
contact customer service.
Visit www.panduit.com for connectivity
Visit www.panduit.com for connectivity
components.
Category 6 U/UTP Copper Cable
Plenum:
PUP6C04*-U
Riser:
PUR6C04*-U
s p e c i f i c a t i o n s
Category 6 cable shall meet ANSI/TIA-568-C.2
Category 6 component standard. The conductors shall
be 23 AWG construction with FEP/polyolefin (CMP) or
polyolefin (CMR) insulation. The copper conductors shall
be twisted in pairs and covered by a low smoke, flame-
retardant (CMP) PVC jacket or a flame-retardant (CMR)
PVC jacket.
a p p l i c a t i o n s
Interoperable and backward compatible, the Panduit TX6
™
Cabling System provides
design flexibility to protect network investments well into the future. With certified performance
to the ANSI/TIA-568-C.2 Category 6 and ISO 11801 Class E standards, this system will
support the following applications:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet),
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet),
10GBASE-T (10 Gigabit Ethernet over limited distances as specified in the industry
10GBASE-T standards)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
k e y f e a t u r e s a n d b e n e f i t s
Third party tested
Cable has been tested as part of the Category 6 UTP
Copper Cabling System by an independent laboratory
and complies with the electrical channel requirements
of the following standard: ANSI/TIA-568-C.2 Category 6
Descending length
Easy identification of remaining cable reduces installation
cable markings
time and cable scrap
Tested beyond the standards
Cable has been characterized to 350 MHz, 100 MHz
above the standard
Easy payout carton
Ensures proper performance and provides
quick installation
t e c h n i c a l i n f o r m a t i o n