Puls ML50.100 Power Supply Guide De Spécification

Page de 20
 
 
 
ML50.100, ML50.109 
 
MiniLine 
 
24V, 2.1A, S
INGLE 
P
HASE 
I
NPUT
 
 
 
Mar. 2007 / Rev. 1.0  DS-ML50.100-EN 
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
2/20 
 
I
NDEX
 
P
AGE
   
I
NDEX
 
P
AGE
 
 
1.
 
General Description ............................................1
 
2.
 
Short-form Data ..................................................1
 
3.
 
Order Numbers....................................................1
 
4.
 
Markings ..............................................................1
 
5.
 
AC-Input...............................................................3
 
6.
 
Input Inrush Current Surge .................................4
 
7.
 
DC-Input...............................................................4
 
8.
 
Hold-up Time.......................................................5
 
9.
 
DC-OK Output .....................................................5
 
10.
 
Output .................................................................6
 
11.
 
Efficiency and Power Losses................................7
 
12.
 
Functional Diagram.............................................8
 
13.
 
Reliability .............................................................8
 
14.
 
Front Side and User Elements.............................9
 
15.
 
Terminals and Wiring..........................................9
 
16.
 
EMC....................................................................10
 
17.
 
Environment ......................................................11
 
18.
 
Protection Features ...........................................11
 
19.
 
Safety .................................................................12
 
20.
 
Dielectric Strength ............................................12
 
21.
 
Approvals .......................................................... 13
 
22.
 
Fulfilled Standards............................................ 13
 
23.
 
Used Substances ............................................... 13
 
24.
 
Physical Dimensions and Weight ..................... 14
 
25.
 
Installation and Operation Instructions .......... 14
 
26.
 
Accessory........................................................... 15
 
27.
 
Application Notes............................................. 16
 
27.1.
 
Peak Current Capability ......................... 16
 
27.2.
 
Back-feeding Loads ................................ 16
 
27.3.
 
Series Operation..................................... 17
 
27.4.
 
Parallel Use to Increase Output Power . 17
 
27.5.
 
Parallel Use for Redundancy.................. 17
 
27.6.
 
Daisy Chaining of Outputs..................... 18
 
27.7.
 
Charging of Batteries ............................. 18
 
27.8.
 
External Input Protection....................... 19
 
27.9.
 
Inductive and Capacitive Loads ............. 19
 
27.10.
 
Operation on Two Phases ...................... 19
 
27.11.
 
Use in a Tightly Sealed Enclosure .......... 19
 
27.12.
 
Mounting Orientations .......................... 20
 
 
 
 
I
NTENDED 
U
SE
 
The power supply shall only be installed and put into operation by qualified personnel.  
This power supply is designed for installation in an enclosure and is intended for the general use, such as in industrial 
control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains and nuclear 
equipment, where malfunctioning of the power supply may cause severe personal injury or threaten human life. 
 
T
ERMINOLOGY AND 
A
BREVIATIONS
 
PE and 
 symbol 
PE is the abbreviation for Protective Earth and has the same meaning as the symbol 
Earth, Ground   
This document uses the term “earth” which is the same as the U.S. term “ground”. 
T.b.d.   
 
To be defined, value or description will follow later. 
AC 230V 
A figure displayed with the AC or DC before the value represents a nominal voltage with 
standard tolerances (usually ±15%) included.  
E.g.: DC 12V describes a 12V battery regardless whether it is charged (13.7V) or discharged 
(10V). As long as not otherwise stated, AC 100V and AC 230V parameters are valid at 50Hz 
and AC 120V parameters are valid at 60Hz mains frequency. 
230Vac 
A figure with the unit (Vac) at the end is a momentary figure without any additional 
tolerances included. 
 
D
ISCLAIMER
 
The information presented in this document is believed to be accurate and reliable and may change without notice. 
The housing is patent by PULS (US patent No US D442,923S) 
 
No part of this document may be reproduced or utilized in any form without permission in writing from the publisher.