Ordering Information
Part Number SAP Number Description
MA9D00-42
1201000005
0º connector, with integrated diagnostics
PA9D0B-42
1201030003
45º connector, with integrated diagnostics
PA9D01-42
1201030001
90º connector, with integrated diagnostics
PA9S01-42
1201030005
90º connector, without diagnostics
PBSTRIP
1201030007
Cable stripping tool
Specifications
Mechanical:
PROFIBUS
9 Pole SubD Pin Headers
Programming/Diagnostics
9 Pole SubD Socket
Insertion (withdrawal) cycles
Min. 200
Cable Type
Solid Core PROFIBUS Type A, EN50170
Cable Diameter
8mm
Screw/Tightening Torque
4-40 UNC/0.4Nm
Enclosure Material
Die-Cast Zinc
Temperature Range
-20°C to +75°C
Cable Connection
IDC Technology
Terminating Resistor
Yes, Built-In Switchable
Bus Signals
Dual, IN and OUT
Insulation Stripping Lengths:
Outer Sheath
17mm
Shield
11mm
LED
Color
LED Off
LED On
LED Flashing at 5Hz
PWR
Yellow
No 5 Vdc Power Supply from
Device
Device
Self Testing
Completed Device
Power OK
Completed Device
Power OK
PB Master Failed or Short Circuit of
Wire
Wire
TxD
Green
No Bus Activity
N/A
Data Transfer in Progress
Term
Yellow
No Termination
Terminator OK
Internal Terminating Resistors Faulty
ERR
Red
No Errors
Faulty Bus
Terminations in The Bus Line
Terminations in The Bus Line
Signal Levels Out of Defined Range
Cable Stripping
Measure wire length as shown
Insert end of cable into stripping tool
and fix it tightly until stopped
PROFIBUS
®
D-Sub Connector
Physical Dimensions
90° Style
Switchable Terminating
Resistors
Resistors
The switchable terminating resistors are
activated by a slide switch accessible from
both the side and rear. With this switch,
the OUT Bus can be shut off. For testing
purposes the PROFIBUS components
following the connector can be switched off
without removing the plug.
activated by a slide switch accessible from
both the side and rear. With this switch,
the OUT Bus can be shut off. For testing
purposes the PROFIBUS components
following the connector can be switched off
without removing the plug.
Cable Installation
Connect Fast! Install Fast!
Troubleshoot Fast!
Troubleshoot Fast!
Loosen the single screw
Lift the contact cover(s)
Push the 2 stripped wires into the wire
channel, lining up with the color code:
Green Line to "A" and Red Line to "B"
Close the contact cover
Tighten the screw securely and you
are finished!
Turn the stripping tool repeatedly
around the cable
Pull off in closed state
Remove wire protection film and
insulation
*Stripping Tool Shown Sold Separately