Cisco CATALYST 4510R 10 SLOT CHASSIS WITH FAN TRAY Guide De Spécification

Page de 15
 
 
© 2005 Cisco Systems, Inc. All rights reserved. 
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com. 
Page 9 of 15 
 
 
Power Supply  
1300W AC  
2800W AC  
1400W DC-P 
4200W AC 
2500W AC 
Input current (rated)  
16A @ 100 VAC,  
7A @ 240 VAC  
16A @ 200 VAC 
Data: 31A @ -60VDC 
Inline: 180A @ -48VDC 
2x 12A @ 100 VAC 
or 
2x 12A @ 200 VAC 
15A @ 200VAC 
Output current (data)  
12V @ 84.7A  
3.3V @ 12.5A 
12V @ 113.3A  
3.3V @ 12.1A  
12V @ 120A 
3.3V @ 10A 
12V @ 115.3A 
3.3V @ 12.5A 
Output current (PoE)  
-50V @ 16.7A 
-50V @ 28A 
-50V @ 140A 
-50V @ 77.1A (200V) 
-50V @ 38A (100V) 
-50V @ 50A 
Output power 
redundant mode (data)  
1000W + 40W  
1360W + 40W  
1367W + 40W 
1360W + 40W 
Output power 
redundant mode (PoE)  
800W 
1400W 
7500W 
3700W (200V) 
1850W (100V) 
2500W (per unit) 
Output power 
combined mode (data)  
1667W  
2473W 
2267W 
2766W 
Output power 
combined mode (PoE)  
1333W 
2333W 
7280W 
7600W (200 V)** 
3782W (100 V) 
Heat dissipation* 
1568 BTU/hr  
2387 BTU/hr  
1591 BTU/hr (data) 
2905 BTU/hr (data and 
PoE) 
3580 BTU/hr 
1210 BTU/hr 
Holdup time  
20 ms  
20 ms  
4 ms 
20 ms 
20 ms 
Number of 802.3af 
Class 2 power devices 
supported with 1 
power supply (1+1)  
101 PDs 
178 PDs 
384 PDs 
384 PDs (200V) 
175 PDs (100V) 
318 PDs 
(per unit) 
Number of 802.3af 
Class 0 and 3 power 
devices supported with 
1 power supply (1+1)  
46 PDs 
80 PDs 
384 PDs 
186 PDs (200V) 
79 PDs (100V) 
144 PDs 
(per unit) 
Cisco phones with 
Integrated PoE*** 
113 PDs 
198 PDs 
384 PDs 
384 PDs (200 V) 
195 PDs (100 V) 
353 PDs 
(per unit) 
Hot swappable  
Yes  
Yes  
Yes 
Yes 
Yes 
Note that calculations for heat dissipation is based on one power supply operating at maximum output power.  
**  Measured when two AC power shelves are strapped together and contain 3x2500W AC power supplies.  
*** Measured when using Cisco prestandard PoE line cards (WS-X4148-RJ45V). 
Additional notes for Table 7 and 8:  
1.
 
Output power is per power supply, unless otherwise stated.  
2.
 
Heat dissipation numbers represent the power-conversion losses of the power supply in operation.  
3.
 