Tascam DR-60DmkII Manuel Du Propriétaire

Page de 133
TASCAM  DR-60DMKII
 35
4 – Recording
CAUTION
Depending on this setting, the input level setting range changes. 
For this reason, the input level might change greatly when this 
setting is changed. Before changing it, you should turn the power 
OFF or turn the output level all the way down.
Using phantom power
When stopped, if you change the 1/L or 2/R input switch on the 
front of the unit to MIC+PHANTOM, a pop-up message appears 
confirming that you want to turn phantom power on. 
When the confirmation pop-up message opens, press the DATA dial 
to turn phantom power on for the 1/L connector or 2/R connector 
and supply phantom power (+24V or +48V) to the connected mic.
To close the confirmation pop-up message without turning 
phantom power on, change the input switch to LINE or MIC
Use the 
SYSTEM
 screen to set the voltage to +24V or +48V. (See 
NOTE
Battery power will be consumed faster when set to +48V than 
when set to +24V.
CAUTION
• 
Confirm that phantom power is OFF before connecting a line 
level device to a 1/L connector or 2/R connector. If you connect 
a line level device while phantom power is being supplied, that 
device and this unit could be damaged.
• 
When using a condenser microphone, before connecting to and 
disconnecting from a 1/L connector or 2/R connector, confirm 
that the phantom power for that jack is OFF. If you connect or 
disconnect a mic while phantom power is being supplied, that 
mic and this unit could be damaged.
• 
Turn phantom power ON only when using a condenser micro-
phone that requires phantom power.
• 
Supplying phantom power to some types of ribbon microphones 
could break them. Do not supply phantom power to a ribbon 
microphone if you are in doubt.
• 
When using USB bus power, the unit might not be able to supply 
phantom power depending on the computer. In this case, use a 
TASCAM PS-P515U AC adaptor (sold separately).
• 
Some condenser microphones will not operate when phantom 
power is set to +24V.
• 
Do not connect or disconnect the AC adaptor when using 
phantom power. Doing so could damage this device.