Visonic Ltd. TOWER12AM Manuel D’Utilisation

Page de 6
D-300909 
TOWER 10 AM, TOWER 12 AM [GRADE 3]
 
 
 
English 
Anti-Masking PIR  and Dual technology (PIR/MW) Mirror Detectors - 
Installation instructions 
Español 
Detectores de espejo (PIR/MW) Doble Tecnología y Anti-Masking 
Portuguese 
Detectores de Espelho PIR e Dupla Tecnologia (PIR/MW) Anti-
Mascara. Instruções de Instalação 
EN: Yellow, red & green LEDs
SP:  LEDs amarillo, rojo y verde
PT:   LEDs amarelo, vermelho e verde
 
Figure 1 TOWER 10 AM / TOWER 12 AM 
 
ENGLISH 
1. INTRODUCTION 
The  TOWER 10 AM PIR and TOWER 12 AM Dual Technology are 
professional vandal resistance Anti-Masking detectors designed for 
large commercial and industrial  applications providing wide coverage 
with superior resistance to harsh environment, employing several 
revolutionary patented technologies
Both detectors comply with EN 
50131 Grade 3. 
Features: 
• V-slot recessed small window technology (patent pending) for 
extreme mechanical robustness and protection from false alarms 
(patent pending). 
• "Obsidian Black Mirrors"™ and "Elliptic / Parabolic Mirror" 
technology providing over 15,000 LUX resistance to white light and 
multiple-solid curtain pattern with 50% better sensitivity than 
comparable mirror optics (several patents pending). 
• Adaptive Active Infra-Red Anti-Masking technology providing the 
most advanced reliable protection against intentional masking 
attempts (patent pending). 
•  Optional interchangeable Long-Range Curtain mirror providing 35m 
x 2.5m (115ft x 8.2ft) coverage for TOWER-10 and 25 x 2m (82 x 
6.5ft) coverage for TOWER-12. 
•  Installer friendly features: 
Built-in selectable E.O.L. resistors for alarm, trouble and tamper outputs. 
Plug-in terminals attached to base for easy pre-wiring. 
Unique sliding closing mechanism with captive screw. 
Extended mounting height 1.5 - 4m (5 - 13 ft.). 
Low supply voltage indication. 
Remote controlled walk-test input. 
Optional mounting brackets. 
Selectable range adapted to the protected area size by use of a 
Range Selector (TOWER 12 AM). 
•  Microprocessor controlled, digital TMR signal processing with dual-
slope digital temperature compensation.  
•  Front and Back tamper. 
•  True "Creep zone" down looking optics. 
•  Pet immunity (18Kg/40lb) using a special "pet mask". 
•  Built-in auto diagnostic for both PIR and microwave detectors. 
2. SPECIFICATIONS 
OPTICAL 
Mirror Types (see Fig. 2) 
 
Wide Angle  
Long Range Curtain 
TOWER 10 & 12 
TOWER 10 
TOWER 12 
coverage 
25mx30m / 90º 
35m / 5º   
25m / 5º  
Far Field Of View (FOV) 
Medium FOV  
11 curtains 
6  curtains 
1 curtain 
1 curtain 
Event counter settings 
1 or 2 
LR 
Mounting:  
Method: Surface, corner or at 45º to wall. 
Height: 1.5 - 4m (5-13 ft.) without bracket. 
Vertical adjustment: Angled base surface provides three tilt 
 
adjustments according to mounting height and coverage range.  
ELECTRICAL 
Sensors type:  
PIR: dual element low noise pyroelectric sensor. 
MW: X-Band Doppler module.  
For UK - 10.687 Ghz, for EU / USA – 10.525 Ghz. 
Supply voltage: 8 – 16 VDC.  
Low voltage detection: If input voltage is below 7.5 VDC.  
Supply current:  
Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12). 
Maximum: 14mA (TOWER 10 AM). 18 mA (TOWER 12). 
Alarm period: 2 to 3 sec. 
Masking detection delay: 30 sec. 
Remote LED enable input (TST): High impedance input. Affects 
LEDs operation only if internal LEDs selector is set to OFF. 
Outputs:  
Alarm output: Solid State Relay. NC, 100 mA / 30 V, 35 ohm 
maximum internal resistance. "Open" for 2 – 3 sec. in case of 
alarm, masking event or complete power failure. 
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm 
maximum internal resistance. "Open" in case of auto-diagnostic 
failure, Anti-Mask event, low voltage or complete power failure. 
Tamper output: NC switch, 50mA / 30 VDC. "Open" by opening 
detector’s cover or removing it from mounting surface. 
Built-in End Of Line resistors circuit: Selectable serial resistors for 
each of the three outputs. Resistors values0 Ohm (Factory default), 
1K, 2.2K, 4.7K, 5.6K Ohm (see figure 5). 
LED indications:
 
Indication 
TOWER 10 AM 
TOWER 12 
Event / status 
Red flashing 
Low voltage 
Yellow + Red  
flashing alternately 
Yellow + Red  + Green 
flashing alternately 
Warm-up 
(60sec.) 
Yellow + Red flashing simultaneously 
Self-test failure 
Yellow  ON 
AM detection 
Red ON 
ALARM 
--- 
Green flashing 
PIR detection 
--- 
Green ON 
MW detection 
Warm-up time: 60 sec.
 
ENVIRONMENTAL 
Operating Temperature: 
–20°C to 55°C   (-4°F to 131°F). 
Storage Temperature: –20°C to 60°C (–4°F to 140°F) 
RFI Protection: Greater than 20 V/m (up to 2 GHz). 
Housing: IP41 and  IK04 . 
 
Dimensions: 160x77x47mm (6-5/16 x 3 x 1-13/16 in.) 
Optional ACCESSORIES:  
BR-1:
 Surface mounted swivel bracket, adjustable 30° down and 45° 
left/45° right.  
BR-2: BR-1 with a corner adapter  
BR-3: BR-1 with a ceiling adapter 
CURTAIN-10/12: Interchangeable long range 35m/5°  curtain mirror 
PET-10/12: Pet mask provides 18Kg/40Lb pet immune for wide angle 
mirror only. 
Standards: 
Designed to comply with EN50131-1 Grade 3 / Class II, 
EN50131-2-2, EN50131-2-4, EN300440, EN301489, EN60950.  
Belgium standard TO14A.  
France standard NF C 48-225, C 48-433, C 48-435. 
3. INSTALLATION 
3.1 General Guidance 
(See figure 3) 
3.2 Installation Procedure 
(See figure 4 & 5). 
3.3 Jumpers setting 
(See figure 5)
 
3.4 Long Range Mirror mounting 
Optional for TOWER-10 AM -
 
See figure 6. For long range mirror, the 
COUNT (counter) jumper should be set to "LR" position (see fig. 5). 
3.5 Pet Mask Mounting (optional) 
For pet immunity (up to 18Kg/40lb), a special "pet mask" model PET 
10/12 should be mounted on the mirror (see figure 6, step 4a).