4. Commissioning 
 
MF0150A2A.doc
            
 
                   Manual for ION-
M7P/85P/17EP/19P
Page 25
 
4.2. Electrical Installation 
4.2.1.  Health and Safety for Electrical Installation 
Read and observe chapter 1.2 Health and Safety
Danger: Electrical hazard. Danger of death or fatal injury from electrical 
current. Obey all general and regional installation and safety regulations 
relating to work on high voltage installations, as well as regulations 
covering correct use of tools and personal protective equipment. 
4.2.2.  Property Damage Warnings for Electrical Installation 
1.  Attention: It is compulsory to ground (earth) the unit before connecting the 
power supply. Grounding bolts are provided on the cabinet to connect the 
ground-bonding cable.  
2.  Attention: If the mains connector of the Remote Unit is not easily accessible, a 
disconnect device in the mains power circuit must be provided within easy reach. 
3.  Attention: A connection of the mains supply to a power socket requires the 
power socket to be nearby the Remote Unit. 
4.  Attention:  Before connecting or disconnecting the mains connector at the 
Remote Unit, ensure that mains power supply is disconnected. 
5.  Attention: Make sure that an appropriate circuit breaker acting as a disconnect 
device (as required by IEC/EN60950-1) and an overcurrent limiting device are 
connected between mains power and the Remote Unit. 
6.  Attention: Incorrectly wired 
connections
 can destroy electrical and electronic 
components.  
7.  Notice: To avoid corrosion at the connectors caused by electrochemical 
processes, the material of the cable connectors must not cause a higher potential 
difference than 0.6 V (see electrochemical contact series). 
8.  Notice:  Use an appropriate torque wrench for the coupling torques: 
 - 
for 7/16 DIN-type (25 N-m / 19 ft lb) with 1 
¼ 
in opening,
 
 
 
e. g. item no. 244377 available from the CommScope e-catalog
 
 - 
for 4.3-10 type connectors (5 N-m, 44 in lb) with 22mm (7/8) in opening, 
 
 
 
e.g. item no. TW-4310
 
9. 
Notice
: : For unstabilized electric networks, which frequently generate spikes, 
the use of a voltage limiting device is advised  
10. Notice: Observe the labels on the front panels before connecting or 
disconnecting any cables. 
11. Notice: Unused connectors must be closed with their protective covers to ensure 
watertightness.