Telensa Ltd. 2N4D Manuel D’Utilisation

Page de 28
 
 
Telecell Installation Manual 
Introduction 
TL-006175-PR Issue 5 © Telensa Ltd 2018 
 
 
  Page 10 
 
 
 
 
 
 
1.5 
Related Information 
[TL-000762-ST] 
System Glossary  
[TL-005536-PR] 
System Overview Manual  
[TL-005716-PR] 
PLANet User Guide 
1.6 
Terminology 
PLANet 
Public Lighting Active Network 
GPS 
Global Positioning System 
OOS 
Orphan Outstation 
OSID 
Outstation Identification Number 
OS 
Outstation 
ROS 
Relay Outstation 
 
1.7 
Essential information 
1.7.1 
Installer 
At the point of installation, it is important to match the Asset ID to the OSID. The installer 
must confirm the correct operation of the Power On / DIM / Off test cycle as follows: 
1) 
Turn ON the mains supply to the Telecell. The lamp will illuminate for 50 
seconds, then turn OFF.  If the unit is fitted with a dimming unit it will illuminate 
for 50 seconds but after approximately 25 seconds it will DIM to approximately 
50%. 
Note:  When powered up, the unit may switch ON then momentarily switch 
OFF, this operation is normal and is the Telecell auto-sensing between 
Analogue and DALI. 
2) 
After 50 seconds has elapsed the lamp will turn OFF.The test is now 
complete.  There is an issue if the lamp fails to operate as described.