      If  tagging  has  failed,  the  message  “FAILURE CODE 1“ will be  
displayed after a few seconds (1 indicating a radio error). 
 
If tagging has been performed correctly, the message  
“SUCCESS“ will be displayed on the screen, followed by the 
unique identification code of the radio interface unit just 
tagged (12 digits).
  2. Special radio tagging procedure for old TBOS™ products 
If the radio interface unit is attached to an old TBOS™ controller and the user performs radio tagging, the irrigation 
program held in the old TBOS™ is automatically transferred to the radio interface unit that then becomes the 
controller.
An empty program is then sent to the old TBOS™ control module that when only serves to control the solenoids.
If network tagging is subsequently performed again, it is an empty program that will be transfer-
red, causing the loss of the interface unit’s program. To prevent this happening, you must remove 
the radio interface unit from the old control module if you which to perform network tagging of a 
module that has already been operated.
 
  3. Changing the network number of TBOS-II™ products 
Each TBOS-II™ field transmitter and each radio interface unit is assigned a network number of “9999“ in the factory. 
This user-modifiable number is stored in the memory of the TBOS-II™ field transmitter and the radio interface unit 
even when switched off.
  
 
      Press OK, select “TBOS Radio“ using the OFF + key and 
confirm by pressing OK.
  
 
 
 
 
  Then, select “Radio tagging“ from the TBOS
TM
 radio menu.  
A message will then appear on the screen. 
  
 
 
 
 
  Select “Network number“. A warning message will automatically 
be displayed informing you of your action.
  
 
 
 
 
  The default network number will be displayed (9999). Use the 
ON OFF keys to change the numbers and arrows to move from 
one number to another.