4.5 RJ45 Seal Kit
If a surge arrestor is not fitted, then the RJ45 seal kit supplied with the link should be used
to connect the Ethernet tail from the ODU to a CAT 5e drop cable, which then connects to
the PoE++ power injector.
to connect the Ethernet tail from the ODU to a CAT 5e drop cable, which then connects to
the PoE++ power injector.
Important: The inner seal supports a maximum Ethernet cable
diameter of 6.50 mm, the use of larger diameter cables will compromise seal integrity.
See section 2.2.6, and also the RJ45 seal kit installation guide.
See section 2.2.6, and also the RJ45 seal kit installation guide.
4.6 Cable installation
The length of the cable from the terminal to the next network component may be up to 100 metres (328 ft), but
should be kept as short as practical in order to reduce voltage drop and signal loss. All Ethernet cables must be
CAT 5e compliant and suitable for outdoor use. The cable must be UV stable and UL approved and must comply
with local and/or national building codes. Cables should be shielded for outdoor use.
should be kept as short as practical in order to reduce voltage drop and signal loss. All Ethernet cables must be
CAT 5e compliant and suitable for outdoor use. The cable must be UV stable and UL approved and must comply
with local and/or national building codes. Cables should be shielded for outdoor use.
4.7 Power injector
The power injector is connected in-line with the data line. The maximum distance between the PoE injector and the
Liberator-V1000
Liberator-V1000
Link is 100 metres (328 ft). The PoE injector must be co
mpliant with “Ultra PoE” (PoE++). To
check that the injector is functioning correctly, use a PoE Tester.
Figure 28 (a) SL Power PENT 1040B PoE++ power injector and (b) PhiHong POE61W PoE++ power injector
Figure 27 - RJ45
Seal Kit installation
Seal Kit installation