4.5 RJ45 Seal Kit 
 
If a surge arrestor is not fitted, then the RJ45 seal kit supplied with the link should be used 
to connect the Ethernet tail from the ODU to a CAT 5e drop cable, which then connects to 
the PoE++ power injector.
 
Important: The inner seal supports a maximum Ethernet cable 
diameter of 6.50 mm, the use of larger diameter cables will compromise seal integrity. 
See section 2.2.6, and also the RJ45 seal kit installation guide. 
 
 
 
 
4.6 Cable installation 
 
The length of the cable from the terminal to the next network component may be up to 100 metres (328 ft), but 
should be kept as short as practical in order to reduce voltage drop and signal loss. All Ethernet cables must be 
CAT 5e compliant and suitable for outdoor use. The cable must be UV stable and UL approved and must comply 
with local and/or national building codes. Cables should be shielded for outdoor use. 
 
 
4.7 Power injector 
 
The power injector is connected in-line with the data line. The maximum distance between the PoE injector and the 
Liberator-V1000
 
Link is 100 metres (328 ft). The PoE injector must be co
mpliant with “Ultra PoE” (PoE++). To 
check that the injector is functioning correctly, use a PoE Tester. 
 
 
 
 
 
 
 
 
 
Figure 28  (a) SL Power PENT 1040B  PoE++ power injector   and  (b) PhiHong POE61W PoE++ power injector 
Figure 27  -  RJ45 
Seal Kit installation