MONITORING SCBA USING THE BASE STATION
Getting Started  
1.  To begin monitoring SCBAs using the base station
software, click INCIDENT, SCBA MONITORING, SCBA
MONITORING in the main screen of the base station
software.  
2.  The SCBA monitoring window will appear.
3.  Check the status of the base station.  
a. The LED labeled “PC Link” will should begin to
alternate from RED to GREEN for approximately 20
seconds.  When the “PC Link” LED stops flashing
and remains GREEN, the base station is ready to
begin logging firefighters on to the system.    
b. The LED labeled “Power” should be GREEN.  If the
“PC Link” light is not GREEN, verify that the base
station is connected properly.  
4.  As firefighters pressurize their SCBA and the ICM TxR
Units are turned on, helmet icons (blue by default) will
appear in the “holding bin” frame of the SCBA moni-
toring window.  The “holding bin” is the white area in
the upper left portion of the window.  When the icon
first appears, it displays “Activated” under the helmet
icon. When the firefighter is fully logged on to the sys-
tem, the helmet icon will change to the color corre-
sponding to the current cylinder pressure.  By default,
the colors indicating cylinder pressure will correspond
with the colors displayed in the NightFighter Heads-
Up Display System receiver.  
Helmet icon in the “holding bin”
5.  The full logon process for a given unit is less than 1
minute.  
a. During the log-on process, the PC acquires data
such as name ID, Team assignment, pressure type,
and current pressure from the ICM TxR Unit. 
b. During the log-on process the helmet icon may
jump from the “holding bin” into a team automati-
cally if a team ID was assigned to the ICM TxR Unit
using an ID Tag.  
c. Refer to the ID Tag Writer Function of this manual
for additional information on team assignments.    
6.  When the helmet icon changes from blue to a color
corresponding to the cylinder pressure (RED, YEL-
LOW, GREEN by default), the ICM TxR Unit has fully
logged on to the base station.  The pressure reading is
the last piece of information that the base station
reads from the ICM TxR Unit before the log on
process is complete. To confirm that a particular unit
has completely logged on to the base station, verify
that the antenna icon in the lower right corner of the
SCBA statistics frame is present.  
On the ICM TxR Unit, an antenna icon will be present in
the upper right corner of the LCD display.    
Note:  If the ICM TxR Unit is turned off
before the full log in processes is complet-
ed, the corresponding helmet icon will
remain in the “holding bin” until the SCBA
monitoring window has been closed.  For
example, if an ICM TxR Unit is turned on
and has begun to log on to the base sta-
tion, if this ICM TxR Unit is then turned off before the log
on process has been completed, a “ghost” icon will
remain in the “holding bin” even though the ICM TxR Unit
has been turned off.  If that ICM TxR Unit is then turned
on again, a new helmet icon will appear and the unit will
begin the log on process again.  In this case, even if the
ICM TxR Unit completes the log in process, a “ghost” hel-
met icon for that unit may remain in the “holding bin” until
USING THE ICM T
X
R ACCOUNTABILITY SOFTWARE
9
TAL 605 (L) Rev. 0 - 10068929