Trilliant Networks Inc. SC1050 Manuel D’Utilisation

Page de 16
SKYPILOT NETWORKS CONFIDENTIAL AND PROPRIETARY 
 
Page  
 
SKYPILOT NETWORKS CONFIDENTIAL AND PROPRIETARY 
13
 
4 Configuration 
 
The SkyPilot system requires minimal configuration before service can be offered. There 
is the option to utilize the SkyPilot Provisioning Server or to manual configure. The 
Provisioning Server, with its interface to an SQL database facilities the configuration of 
large scale networks. The Provisioning Server is the topic of a separate document. This 
document shall focus on the manual configuration of CPE (SC1050) units. 
 
4.1 CPE 
Configuration 
 
A CPE must be configured for the following: 
 
1.  IP Address Mode – DHCP or Manual 
2.  Management IP Address and Mask (if manually configure) 
3.  Ethernet Port Control 
4.  QoS Data Rates 
 
4.1.1  IP Address Management 
 
The CPE management interface (SNMP, Telnet) requires the allocation of an IP address. 
It can be configured to use either DHCP for dynamic IP address allocation or can be 
statically configured via the CLI.  
 
DHCP is the default. For static allocation the IP Address, Netmask and IP Default 
Gateway must be input via the CLI. See Section 5 for details. 
 
4.1.2  Ethernet Port Control 
 
The CPE allows for the disabling (and enabling) of the 10500bT Ethernet port. Default is 
disabled. The enable/disable Ethernet port facility can also be used to control subscriber 
access. 
 
4.1.3  Subscriber Data Rates 
 
The CPE allows for configuration of maximum downstream and upstream data rates. The 
values relate to traffic sent and received over the Ethernet port.