Shyam Telecom Inc. R20-1900 Manuel D’Utilisation

Page de 41
 
 
                                                                                       Page 
All Rights Reserved                      Shyam Telecom Limited                                  35/42 
Next Generation 
Signal Enhancement
4. Review the intended coverage area according to the site installation 
plan. Using a mobile NOKIA handset loaded with NET engineering 
software and the SIM card of cellular operator, measure and monitor 
the signal level at various points within and around the perimeter of the 
coverage area.  
8.7.  Dos & Don’t Dos  
           
1.  The site should be accessible for the maintenance team. 
2. Arrangement is to be made to avoid unauthorized access to the 
repeater. 
3.  Proper earthing of the repeater is required to be done to avoid damage 
to the system. 
4.  The housing should be kept away from direct exposure to the Sunlight, 
chemical fumes & excessive moisture.  
5.  Stable power supply for repeater unit should be ensured. 
6.  The route of Cables to/from antennas should be short to limit the cable 
losses and should be free from sharp bends & kinks. 
7.  Local standard of cabling should be followed. 
8.  The donor antenna should have proper line of sight with the BTS from 
where the signals are to be intercepted for maximum signal strength 
and to reduce the effect of fading. 
9.  There should be adequate separation of antenna system from power 
lines to avoid damage to system. 
10. The selection of BTS should be made taking other BTSs in the same 
vicinity in to consideration to avoid interference. 
11. Gain of the repeater should be set after taking antenna isolation in to 
consideration. 
12. The estimation of coverage area should be confirmed. 
13. The system should be made over for normal traffic after actual 
measurement of: 
a) 
RF power in the DL 
b) 
RF power in the UL 
c) Antenna 
Isolation 
d) 
Gain settings in DL & UL 
14. Feedback regarding performance of the system must be obtained from 
the user.  
 
8.8. LED Display On R-20 Unit 
      In order to facilitate the maintenance team, a set of LEDs are provided on 
the top cover of the unit which display some of the important events in the 
system, the detail is given below: