Sena Technologies Inc. PARANISD1100 Manuel D’Utilisation

Page de 48
 22
3. Multiple Connection Mode 
 
 
3.1. Overview 
 
Parani-SD1100 supports multiple connections up to 4 slave units. There are two types of multiple 
connection modes: Multi-Drop Mode and Node Switching Mode. 
 
 
 
Figure 4-1 Multi-Drop Mode 
 
In Multi-Drop Mode a master unit can connect to maximum 4 slave units at the same time and they 
transfer data bi-directionally as in Figure 4-1. 
 
 
 
Figure 4-2 Node Switching Mode 
 
In Node Switching Mode, the master unit maintains multiple connections with maximum 4 slave units 
but only one connection with one slave unit is active and data is transferred as shown in Figure 4-2. 
Active slave is selected by AT commands. 
 
 
 
 
 
 
 
 
 
 
 
 
 
On communication after connecting 
 
+++ 
 
OK 
 
ATO1 – Communicating with #1 Slave 
 
+++ 
 
OK 
 
ATO000195000003 – Communicating with slave of BD 000195000003