MTI Co. Ltd. RF25-MWM101 Manuel D’Utilisation

Page de 36
 
 
 
 
 
 
 
 
BDA Installation and Operating Guide 
Version 1.0                                                                          34 
4    Appendices. Alarm Reference List 
 
 
Alarms 
Related Module 
or Unit 
Alarm Level 
Description 
Shutdown 
"
 When Over Power Alarm occurs, shutdown and retrial of enabling is repeated five 
times. If Over Power Alarm still continues, there are no more retrials and Shutdown 
Alarm is displayed. Cause of the problem must be removed and the repeater unit 
must be manually switched on.   
DL shutdown 
HPA 
Critical
 
"
 This alarm is to protect HPA, confining 
output power of HPA. 
UL Shutdown 
HPA 
Critical
 
"
This alarm is to protect BTS, confining  
reverse power of HPA.     
Over 
Temperature 
"
 These alarms occur when detection level of the temperature is higher than that set in 
the GUI. The repeater unit is operating normally. 
Over 
Temperature 
Inside of BDA 
Minor 
"
 It occurs when detection level of the 
temperature is higher than specified value.
DL/UL 
PLL_LD 
Transceiver Major 
"
 This alarm is to protect transceiver. 
"
 This alarm occurs when PLL of the 
transceiver is unlocked.   
"
 If this alarm occurs when transceiver is not 
operating normally.