904.200.17 RFID/2 reader
Proximity reader module
for passive, 125KHz , inductive tags.
(S/n 1707xxxx and subsequents)
Transponder type
64bit Read only H4102 compatible. 125KHz standard.
Interface
Magstripe reader emulation (buffered) (14 decimal digits). Alternatively 9600bps
serial ASCII, or Wiegand 26bit, or Barcode C39 emulation output.
Reading range
Minimum 12cm at 5..12Vdc, with ISO card, in good conditions.
Don’t mount the reader directly on metal surface.
Audio-visual
indication
indication
Two LEDs (Red and Green) driven by connecting the Grey and Yellow wires, respectively, to GND.
If the Grey wire is not connected, the Red LED automatically turns on in case of good decode, then turns off
only when the tag exits the reading range.
only when the tag exits the reading range.
Buzzer activated on good decode.
Power supply
5-18 Vdc., 65mA typical with a 12V supply.
Dimensions
101 x 44 x 23 mm (outline)
Temperature range
-20° to +60°C.
Interface Cable
300 cm
AXESS TMC srl
Via della Filanda, 22 - 40133 Bologna - Italy
Tel:+39 051 3519311 - Fax: +39 051 3519399
www.axesstmc.com
Output for TMC PROX & TRAX
1
(n.c. battery aside)
2
Pink
Clock Output
3
White
Data Output
4
Blue
GND
5
Red
Power 5Vdc
Connector
The 904.200.17 is supplied with a 8-pin MOLEX
connector. It is factory configured for using (as a magnetic
emulation reader) with TMC 914.003.20 HotMAX boards.
Connection to Prox (and Trax) terminals is also possible
changing the pins order and reducing the connector as
shown in the rightmost table.
connector. It is factory configured for using (as a magnetic
emulation reader) with TMC 914.003.20 HotMAX boards.
Connection to Prox (and Trax) terminals is also possible
changing the pins order and reducing the connector as
shown in the rightmost table.
Note:
to modify the pin connections or change the
connector size, just press a little with a screwdriver into
the corresponding rectangular hole and pull the wire at the
same time. Then re-insert it in the required position.
the corresponding rectangular hole and pull the wire at the
same time. Then re-insert it in the required position.
Configuration wires and output assignments
C
LK
D
ATA
M
AG
S
TRIPE
14
DIGITS (
DEFAULT
)
W
IEGAND
26
BIT
B
ARCODE
C39
14
DIGITS
S
ERIAL
9600
N
81
<
STX
>10
HEX DIGITS
<
CR
><
LF
><
ETX
>
S
ERIAL
9600
N
81
14
DEC DIGITS
<
CR
>
Red
Power 5 - 18 Vdc
Blue
GND
Pink
Clock
Data1
Data
Wired with Brown
N.C.
White
Data
Data0
Wired with Brown
TXD
Brown
CARD PRESENT
Wired with GND
Wired with White
Wired with Pink
Wired with Green
Green
N.C.
Wired with Brown
Yellow
GREEN LED command (to GND)
Grey
RED LED command (to GND)
Output Assignment for TMC MAX
1
Blue
GND
2
3
Pink
Clock Output
4
Red
Power 5 - 18 Volt
5
White
Data Output
6
7
Yellow
GREEN LED
8
Grey
RED LED
This device only conforms to
all the standards of the CE
mark if the installation and
user instructions contained in
this document are followed
correctly.
1 2 3 4 5 6 7 8
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference. Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
INSTRUCTIONS FOR FCC ID LABELING
Module type: transmitter 90401-17
FCC-ID: SYL90401-17
This intends to inform you how to specify the FCC ID of our transmitter module 90401-17 on your final product. Based on the Public Notice from FCC, the
product into which our transmitter module is installed must display a label referring to the enclosed module. The label should use wording such as “Contains
transmitter module FCC ID: SYL90401-17” or “Contains FCC ID: SYL90401-17”, any similar wording with the same meaning may be used.
Module type: transmitter 90401-17
FCC-ID: SYL90401-17
This intends to inform you how to specify the FCC ID of our transmitter module 90401-17 on your final product. Based on the Public Notice from FCC, the
product into which our transmitter module is installed must display a label referring to the enclosed module. The label should use wording such as “Contains
transmitter module FCC ID: SYL90401-17” or “Contains FCC ID: SYL90401-17”, any similar wording with the same meaning may be used.