Alarm 
secondary alarm opens during Maintenance Lockout state. 
 
Impact Lift Interrupt 
When this field is checked, the circuit wired to interrupt the 
Vehicle lift opens during Impact state (lift interrupt created). 
 
Impact Secondary Alarm 
When this field is checked, the circuit wired to create a 
secondary alarm opens during Impact state. 
 
Impact Delay (seconds) 
For the defined period of time, there is a delay before the Lift 
Interrupt and Secondary Alarm circuits open, after entry to the 
Impact state. 
 
Battery OK To Charge Threshold 
(SGP) 
Set the upper limit of the OK To Charge battery state in 
specific gravity points according to your company’s battery 
charging policy.  See RECOMMENDED SETTINGS. 
 
Battery OK To Charge Timer 
(minutes) 
The Vehicle Interface displays “BATTERY OK TO 
CHARGE” when the battery has been monitored below the 
OK To Charge Threshold for this period of time.  See 
RECOMMENDED SETTINGS. 
 
Battery Must Charge Threshold 
(SGP) 
Set the upper limit of the Must Charge battery state in specific 
gravity points according to your company’s battery charging 
policy.  See RECOMMENDED SETTINGS. 
 
Battery Must Charge Timer (minutes)  The Vehicle Interface displays “BATTERY MUST 
CHARGE!” when the battery has been monitored below the 
Must Charge Threshold for this period of time.  See 
RECOMMENDED SETTINGS. 
 
Battery Must Charge Lift Interrupt 
When this field is checked, the circuit wired to interrupt the 
Vehicle lift opens during Must Charge state (lift interrupt 
created). 
 
Battery Must Charge Secondary 
Alarm 
When this field is checked, the circuit wired to create a 
secondary alarm opens during Must Charge state. 
 
Battery Must Charge Delay (minutes)  For the defined period of time, there is a delay before the Lift 
Interrupt and Secondary Alarm circuits open, after entry to the 
Must Charge state. 
 
Battery Fault Lift Interrupt 
When this field is checked, the circuit wired to interrupt the 
Vehicle lift opens during Battery Fault state (lift interrupt 
created). 
 
Battery Fault Secondary Alarm 
When this field is checked, the circuit wired to create a 
secondary alarm opens during Battery Fault state. 
 
Battery Fault Delay (minutes) 
For the defined period of time, there is a delay before the Lift 
Interrupt and Secondary Alarm circuits open, after entry to the 
Battery Fault state.