Hitachi Kokusai Electric Inc. SL24G-US-02 Manuel D’Utilisation

Page de 108
7. Appendix
 
 
7-1 Product specifications 
 
 
88
Item 
Specification 
Remarks 
Interference prevention 
function 
Based on the link ID identifier 
 
Carrier sense function 
Yes 
 
Interference avoidance 
function 
If there is continued interference during carrier sense 
or wireless communication, the wireless channel is 
automatically changed after the appropriate 
adjustments are made. 
 
Antenna power control 
Monitors the receive power of the opposed device 
and optimizes the output power   
Shortest communication distance 5m
Excess input protection 
Yes 
 
Security functions 
  Unique wireless protocol and data scrambling 
 Web maintenance and TELNET maintenance 
login password 
 
Maintenance function 
The following items can be controlled over a LAN: 
  Control using HTTP, SNMP and TELNET 
  Wireless settings, SYSLOG, SNTP settings 
  Status and log display 
  Settings information, firmware updates 
IEEE802.1Q: Supports maintenance 
with VLAN tags 
SNMP SNMPv1 
  MIB-II system, interface groups 
 Private MIBs 
 Traps 
 
LAN interface 
100BASE-TX 
100Mbps full duplex 
Maximum packet length  1536 bytes 
 
Received power monitor 
terminal 
Outputs DC voltage based on the receive power of 
the opposed device and the output power of this 
device. 
 
Power consumption 
IEEE802.3af PD CLASS 0 compliant 
12.95W or less 
 
Power supply 
Through DC added to a LAN cable 
Supply length: 100m or less 
 
Size 
Approx. 290(W) x 290(H) x 70(D) mm 
Not including the metal mounting 
bracket 
Mass 
Approx. 3.5 kg 
Not including the metal mounting 
bracket 
Accuracy of the built-in 
clock 
Error: 2 to 3 mins/month 
 
Waterproof 
IPX4 (IEC 60529) 
 
Dust protection 
IP5X (IEC 60529) 
 
Survival wind speed 
Up to 90m/sec 
No damage 
Wind pressure load 
(at a wind speed of 
90m/s) 
  For main unit 
490 N (50 kgf) 
Not including the safety factor 
Theoretical calculation value 
Diameter of the pole for 
attaching the metal 
mounting bracket 
φ
25 to 51 mm 
 
Operating temperature 
range 
-20˚C to +50˚C 
(including when the power is turned ON) 
Ambient temperature 
Operating humidity 
range 
Up to 95% 
 
Corrosion protection 
Sea air resistant specification 
 
The equipment has resistance to sea 
air, but it is not completely resistant to 
corrosion. Perform the installation 
and maintenance appropriately. 
Environmental conditions  No flammable or corrosive gases