Mitel Deutschland GmbH 68635RFP36U-01 Manuel D’Utilisation
SIP-DECT OM System Manual
238
You cannot change the IP address value when you select more than one RFP.
If more than one parameter value is allowed (e.g. Router, DNS addresses), you must separate the
values by a space.
values by a space.
If you click the
Reset Configuration button, all configuration parameters are removed and local
configuration in the OM Configurator is disabled. The
Send Configuration option is also needed in this
case in order to update the configuration of the RFP locally.
When you click the
OK button, changed parameter values are committed to the database. The system
performs validation checks for some parameter values. If this check fails, the system displays an error
message in the Info console and the misconfigured parameter value is marked with a red frame (allowing
you to correct the value). Modified RFP records are marked (
message in the Info console and the misconfigured parameter value is marked with a red frame (allowing
you to correct the value). Modified RFP records are marked (
) beside the corresponding table row.
If you press
Cancel or select another RFP in the table, any changes are discarded.
When you press either
OK or Cancel, the Detail Data panel disappears and a number of task bar
options (e.g.
Send Configuration) are re-enabled.
7.7.6.1 Other parameter panel
You can set and edit less frequently used parameters on the
You can set and edit less frequently used parameters on the
Other panel of the Detail Data window.
If the parameter you want to add or edit is listed in the table on the
Other panel, click on it to display the
parameter name and value in the fields on the top-right side of the panel. Click the
Change button to
commit the changed value.
If the parameter value field is empty, the parameter is cleared on the RFP when you click
Send
Configuration.
You can add a new parameter by selecting a parameter name from the drop-down list and clicking the
New button.
You can add a new parameter by selecting a parameter name from the drop-down list and clicking the
New button.
7.7.6.2 Copy and Paste
You can assign parameter values from one RFP to one or more other RFPs.
You can assign parameter values from one RFP to one or more other RFPs.
To perform this operation, you must ensure that the
Detail Data window is not active. If the Detail Data
window is open, commit your changes or cancel to close the window.
Select an RFP in the table and click the
Copy Configuration option in the task bar. Next, select one or
more RFPs as destination RFP(s) and click the
Paste Configuration option. The system displays the
Paste Data dialog window.
If the
Assign IP Addresses option is enabled, you must provide a valid IP address in the Start Address
field. The system may display a suggested address, based on a previous paste or Add RFP operation.
The IP address is incremented by one for each RFP.
The IP address is incremented by one for each RFP.