Geonautics International Pte Ltd 30-0710 Manuel D’Utilisation
TAG-T3 Wombat – User Guide, 1.0.7
Commands
4.7
TRX
4.7.1 TRX (Configuration)
Specifies the TRX operational parameters.
$GO0,,TRX[,<Interval>][,<Period>][,<Power Management>]
$GOA,<Unit_Id>,TRX,<Interval>,<Period>,<Power Management>
GSM Command
Description
Interval
Number of seconds between the TRX
turning on
turning on
Period
Number of seconds for the TRX to stay
ON, minimum 60 secs
ON, minimum 60 secs
0 TRX ON according to Interval and Period
timers
Power Management
1 TRX ON during each Interval and when
movement sensed
Table 15, TRX Command
Default:
$GO0,,TRX,1800,180,0
Example:
$GO0,,TRX,0,180,0
Returns:
$GOA,<Unit_Id>,TRX,0,180,0
Setting the TRX interval to zero forces the TRX to be permanently on.
The interval is aligned to the start time and local time parameters of
the Clock command of page 21.