AP400 
– All Types Installation Manual 
Page 13 of 34 
© NEC  Nederland B.V.  2011 
 
 
DAP Controller - Selective Countries.  
This version is used in countries with frequency ranges other than EMEA or North 
America. 
Note: 
In North America, only the “DAP Controller - North America” will be delivered, so 
no other frequencies than the North America frequencies and power levels are 
possible in North America. 
Note:  In Europe, only the 
“DAP Controller - International” will be delivered, so no other 
frequencies than the European frequencies and power levels are possible in 
Europe. 
 
1.3 
SITE REQUIREMENTS 
Usually the Cabinets will be fixed to existing walls in the positions determined by the Site 
Survey. 
Do not mount the AP400 to a metal wall! 
 
1.4 
TEMPERATURE RANGES 
The temperature ranges of the AP400:  
 
Temperature range AP400:  -5  to 45  C. 
The AP400 should not be exposed to sunlight! 
The outside temperature range for the AP400 (all types) mounted in the Outdoor Cabinet 
is as follows: 
 
Minimum outside temperature: -20  C 
 
Maximum outside temperature: 45  C  
The Outdoor Cabinet should not be exposed to sunlight! 
 
1.5 
CABLE SPECIFICATIONS FOR AP400 Types 
The cabling to the AP400(E) should be 
“Category 5” or “Category 6” Ethernet cabling. The 
interface is defined as an SELV interface according EN60950-1.  For this reason the 
safety restriction as given in the next chapter should be respected: