Geoforce Inc. 00GT1 Manuel D’Utilisation

Page de 5
GT-1 Maintenance 
The Geoforce GT-1 is a low maintenance global tracking device.  
User based maintenance is limited to the following: 
1)  Periodic battery changes when battery life runs low. 
 
To change the GT-1 batteries: 
1)  Locate the T-27 security torx bit driver 
2)  Remove the 4 tamperproof torx screws from the GT-1 metal enclosure 
3)  Remove the upper metal enclosure half and white electronics housing from the lower metal enclosure 
a.  Take care to not let any water drip into the battery compartment 
4)  Remove and replace all 6 batteries with provided GT-1 battery replacement kit (part # AO-GT1-BATT) 
5)  Place GT-1 white electronics housing back into lower metal enclosure 
a.  Alignment tab on end of white plastic housing should line up and nestle into enclosure slot 
6)  Place upper metal enclosure half back in place 
7)  Secure the 4 tamperproof torx screws, maximum torque 6-­­10ftlbs. [8-­­13Nm] 
 
WARNING: DO NOT open the GT-1 metal enclosure or replace the batteries while an explosive or hazardous 
environment in present.  
WARNING:  Replace  the  GT-1  batteries  ONLY  with  approved  Geoforce  provided  3.6V  batteries.  Using  any 
other batteries will void the entirety of GT-1 intrinsic safety.