Intel P4304BTSSFCN Manuel D’Utilisation

Page de 20
Monthly Specification Update 
Enterprise Platforms and Services Marketing 
 
10 
Problem             When running PCT(platform confidence test utility) on Intel
®
 Server Board 
S1200BTL, PCT reports "Processor Does Not Support Brand ID". 
Implication          This is actually not an error message, it indicates that this Processor ID is not 
in the list of processors can be recognized by PCT. 
Status                 Fixed in PCT1.04 V02 tool. 
Workaround       N/A. 
23.  The SEL is keep reporting when RAID is rebuilding on Intel® Server 
System R1304BTLSHBN 
Problem 
When the RAID is rebuilding, the Rebuild/Remap is recorded in SEL until the 
SEL is full.
 
Implication 
The user will see the hot swap backplane rebuild SEL. 
Status 
Fixed in BMC Rev. 1.10. 
Workaround 
None 
24.  The system can not detect more than 8 USB devices 
Problem 
On Intel
®
 Server Board S1200BTL/S1200BTS, the board can not detect more 
than 8 USB devices. It can only detect 8 USB devices or less than 8 USB 
devices.
 
Implication 
The BIOS fails to control the USB controller if more than 8 USB devices 
plugged in. 
Status 
Fixed in BIOS Rev.30. 
Workaround 
None 
25.  The board will allocate about 250MB memory for PCIe device under 
Microsoft* windows OS 
Problem 
On Intel
®
 Server Board S1200BTL/S1200BTS, the board will reserve 250MB 
memory for PCIe device under Microsoft* windows OS. 
 
Implication 
The memory size showed in Windows* OS will be the memory the user installs 
minus about 250MB. For example, if there is 1GB memory installed in the 
board, the Microsoft* Windows OS will show about 750GB. 
Status 
Will not fix. 
Workaround 
None