Wavenet Technology Pty Ltd. BM2900D Manuel D’Utilisation

Page de 147
Boomer II User Manual & Integrator’s Guide ________________________________ Appendix A - NCL INTERFACE 
 
BM210012WT37 
79 
Copyright Wavenet Technology © November 2003 
Appendix A - NCL Interface 
The Boomer II is compliant to Native Control Language (NCL) 1.2. 
Wavenet Vendor-specific extensions are also listed here.  
The specification for the NCL protocol may be obtained in Adobe 
Acrobat format from the Motorola website at 
Please note that the Boomer II modem can also be configured to 
approximate a Hayes protocol.  See the document “BM2100ATWT04 
Boomer-II AT Communications API” available from Wavenet for 
further information. 
Generic NCL (Native Mode) 
 
Command SDUs (CMND, ASCII A) 
Commands 
Value 
Parameters 
Value 
Sub-values and Descriptions 
SEND 
ASCII 1 
 
 
Send message. 
READ_MSG 
ASCII 2 
 
 
Read queued message in RPM. True only if confirmed delivery mode 
enabled. 
CTL_EVENT 
ASCII 3 
Event Report SDUs. 
 
Control event. 
GET_STATUS 
ASCII 4 
 
 
Get RPM status/configuration. 
 
 
R_CONFIG_BLOCK 
ASCII A 
Get RPM configuration block. 
  
R_RF_BLOCK 
ASCII 
Vendor-specific: Get RF status block. 
 
 
R_STATUS_BLOCK 
ASCII B 
Get RPM status block. 
 
  
R_PROD_ID 
ASCII 
Get RPM product ID: 
 
RF_RDLAP_9.6 
RF protocol is RD-LAP 9600. 
ASCII 0 
RF_RDLAP_19.2 
RF protocol is RD-LAP 9200. 
ASCII 1 
RF_MDC4800 
RF protocol is MDC 4800. 
ASCII 2 
RF_DUAL 
Dual RD-LAP 9.2/MDC4800. ASCII 
NCL_PRE1.2 
NCL support is R1.0 or R1.1. 
ASCII 0 
NCL_1.2 
NCL support is R1.2. 
ASCII 2 
 
  
R_SYSID 
ASCII 
Vendor-specific: Get system ID of current RF system. 
 
 
R_SW_VERSION 
ASCII D 
Get software version number. 
 
 
R_RPM_ID 
ASCII E 
Get RPM address. 
 
 
R_RF_BLOCK_SHORT 
ASCII E 
Vendor-specific: Get short form of RF status block. 
  
 
ASCII 
Reserved. 
 
 
R_MAX_DATA_SIZE 
ASCII G 
Get SDU data limit. 
 
 
R_RPM_GID 
ASCII H 
Get RPM group IDs. 
 
 
R_WAN_TYPE 
ASCII I 
Get WAN Type Code. 
 
 
R_RF_VERSION 
ASCII J 
Get RF protocol version number. 
 
 
R_VENDOR_ID 
ASCII K 
Get vendor information: VEND_MOTOROLA Vendor is Motorola 
ASCII 0 
  
 
ASCII 
L..Z 
Reserved. 
 
 
R_RCV_MODE 
ASCII a 
Get mode of notification to the DTE for received SDUs.