Wavenet Technology Pty Ltd. BM3900M Manuel D’Utilisation

Page de 90
Boomer-III User Manual & Integrator’s Guide____________________________________________ Modem Test Jig 
BM310012WT05 
57 
Copyright Wavenet Technology © October 2003 
Initial Calibration 
Without connecting a Boomer-III OEM Modem to the Test Jig, 
initially check the calibration of the on-board voltage regulator. (This 
regulator supplies the RS232 converter and other on-board circuitry 
only. It does not supply power to the modem). 
1.  Connect the centre pin of the DC jack to the +3.8V power 
supply with 2A capability and the external pin to the ground. 
2.  Adjust the trim pot marked ADJ VCC to make sure the voltage 
on the test pin next to the ADJ VCC is 3V. 
3.  Keep all of the switches on the dipswitch in the off position 
(except DIP switch 2) for normal modem operation. 
Fitting the Boomer-III Modem 
With the power off, 
1.  Connect the Boomer-III OEM modem to the lower FPC 
connector on the test jig using a 30-way FPC cable.  
Use the following procedure to insert the cable into the FPC 
connector. 
a.  Lift up the lock lever of the FPC connector by flipping it 
up with the nail of your thumb or index finger. 
 
 
 
b.  Ensure that the cable is inline with the connector and 
insert the FPC cable into the connector with the 
conducting surface of the cable facing downwards. 
 
 
Lock Lever 
FPC conductor side