Xeline Co. LTd. MM-202BX Manuel D’Utilisation

Page de 14
                                
MM-202BX 
Installation Manual
 
This document is subject to change without prior notice.
 
 
11 
4.4 Connecting the MM-202BX to the ISP Backbone 
Note: To connect multiple MM-202BX units and the EU-200BX EMS unit, it is recommended to 
prepare a Switch Hub in advance for installation.   
 
① 
Check the connection between the backbone and Switch Hub. 
② 
Connect the UPLINK port of the MM-202BX to the Switch Hub using the RJ-45 cable.   
 
 
 
 
 
 
 
 
 
 
 
Figure 6 Connecting the MM-202BX to the ISP backbone 
 
③ 
Once the MM-202BX is connected to the backbone, turn on the power of the MM-
202BX. 
④ 
Wait approximately  3 minutes for the EU-200BX to finish the remote  registration 
process. 
 
4.5 Checking the Final Connections 
Note: When using the SU-200BX test unit, make sure it is set to Factory Default mode.
4
   
 
4.5.1 Checking the Ethernet connection 
① 
Connect the laptop PC to the LAN port of the MM-202BX using a RJ-45 cable. 
② 
Configure the network properties of the laptop PC as provided by the ISP.  
③ 
Confirm if the Internet connection is working properly.       
 
4.5.2 Checking the PLC connection using the SU-200BX test unit 
① 
Turn off the power of the MM-202BX. 
② 
Disconnect ALL cables (including the RJ-11 cable) from the MM-202BX except for the 
                                                 
4
 
Please refer to the SU-200BX Installation Guide for details on resetting to Factory Default 
mode. The ACT LED of the SU-200BX will blink when successfully changed to the factory 
default mode.
 
MM-202BX