SystemBase Co. Ltd. WCS-232V50 Manuel D’Utilisation

Page de 4
User’s Manual
WCS-232 v5.0
User’s Manual
WCS-232 v5.0
User’s Manual
WCS-232 v5.0
User’s Manual
WCS-232 v5.0
R
R
A
W
A N
T
5
YEAR
SystemBase Co., Ltd. warrants that the product(s) shall be free from
manufacturing defects in materials and workmanship for a period of
five (5) years from the date of delivery provided that the product
was properly installed and used. Defects, malfunctions or failures of
the warranted product caused by damage resulting from acts of God
(such as floods, fire, etc.), environmental and atmospheric disturbances,
other external forces such as powerline disturbances, host computer
malfunction, plugging the board in under power, or incorrect cabling
and damage caused by misuse, abuse and unauthorized alteration or
repair are not warranted.
The warranty is limited to the repair and/or replacement, at SystemBase's
option, of the defective product during its warranty period. Customer
must obtain a Return Material Authorization (RMA) number prior to
returning the defective product to SystemBase for service. Customer
agrees to insure the product or assume the risk of loss or damage in
transit, to prepay shipping charges and to use the original shipping
container or equivalent. Contact SystemBase Customer Support at
tech@sysbas.com for further information. Product replaced shall be 
warranted for a period of ninety (90) days or the duration of the initial 
product warranty period, whichever is longer.
THE PROVISIONS OF THE WARRANTY ARE IN LIEU OF ANY OTHER
WARRANTY, WHETHER EXPRESSED OR IMPLIED, WRITTEN OR
ORAL, AND SYSTEMBASE'S LIABLITY ARISING OUT OF THE
MANUFACTURE, SALE OR SUPPLYING OF THE PRODUCT AND ITS
USE, WHETHER BASED ON WARRANTY, CONTRACT, NEGLIGENCE,
PRODUCT LIABILITY OR OTHER WISE, SHALL NOT EXCEED THE
ORIGINAL COST OF THE PRODUCT. IN NO EVENT SHALL
SYSTEMBASE BE LIABLE FOR UNINTENDED OR CONSEQUENTIAL
DAMAGES, INCLUDING, BUT NOT LTMITED TO, LOSS OF PROFITS
OR USE DAMAGES ARISING OUT OF THE MANUFACTURE, SALE
OR SUPPLYING OF THE PRODUCT.
Help Hotline : Technical supports are available to all our customers
                               for assistance in installation and operation.
                               [+82-2-855-0501]
                               e-mail: tech@sysbas.com
5-Year Warranty
WCS-232 v5.0
16F Daerung Post Tower-1, 212-8, Guro-dong, 
Seoul, Korea / Tel. 82-2-855-0501 / Fax. 82-2-855-0580
www.sysbas.com / www.solvline.com / marketing@sysbas.com  
User’s Manual
   Version 1.0
RS232 to Bluetooth Converter
1
 
2
 
3
 
4
 
5
 
6
 
1. Preface
Thank  you  for  purchasing  product  by  SystemBase.  This 
product  has  passed  thorough  quality  control  and  during 
the  5  year  warranty  period,  the  customers  can  get  free 
repair  services  from  the  day  the  purchase  was  made.  If 
you  have  any  questions  or  difficulties  with  this  product 
please contact our Technical Support at http://www.solv-
line.com.
2. Introduction
●  This  is  a  converter  which  changes  RS232  signal  to 
Bluetooth signal or vice versa.
●  The following is the contents in the package.
· WCS-232 v5.0 2EA
· 1dB antenna 2EA
· User manual
· USB power cable 2EA
3. Specification
3.1 Serial Communication
Communication Interface
RS232
Communication Speed
Max. 230.4kbps
Communication Distance
Max. 15m
Connector
DB9 Female 
3.2 Bluetooth Communication
Specification
Bluetooth Specification V2.1 
+ EDR class 1
Frequency
2402 ~ 2480 MHz
Wireless method
Frequency Hopping Spread 
Spectrum 
Maximum
Communication Distance
100m
3.3 Hardware
Power Supply
5V from USB port on the PC 
Can be used with 5~12V DC adapter
Dimension
36.8(W) x 19.0(D) x 74.2(H)
Weight
35g
4. Structure
4.1 External Form
4.2 Hardware 
SETUP 
 ACTIVE :  Active Mode
SETUP 
 ACTIVE :  Setup Mode
4.2 Switch Mode
- LINK:  When the power is supplied, red LED starts 
blinking. When connected with the target 
wirelessly, green is on.
- TXD:  When a data is transmitted LED is on. 
(When it is in linked status LED is dimmed.)
- RXD: When a data is received LED is on.
5. Connector
RS232 DB9 Female
 
6. Installation 
6.1 Connect 
Connect  WCS-232  to  a  serial  port  on  a  PC  or  a 
communication device and supply power.
LINK 
TXD 
RXD 
RS-232 Side (DB9)
Female Connector
Antenna
ACTIVE MODE
Mode Switch
SETUP MODE
WCS-232  can  get  the  power  from  USB  cable 
connected to the USB port on the PC.
When  both  WCS-232  is  powered  up,  they  will  be 
connected  using  Bluetooth.  This  is  when  you  can 
start using the serial port.
6.2 Environment Setting
Since  WCS-232  is  connected  to  the  serial  port, 
serial  related  settings  (baud  rate,  data  bit,  parity 
bit,  stop  bit,  and  flow  control)  and  RF  related 
configurations (name of the device, operation mode, 
target  address)  are  required  to  be  set.  Regarding 
RF connection settings, if WCS-232 is not trying to 
connect to other WCS-232 but Bluetooth device from 
other companies or when trying to reset the settings 
to the factory default, it is required.
6.3 WCS-232 Setup Utility Installation
Run  WCS-232  Setup  Utility.  You  can  download 
the file from our homepage or find it from the CD 
included in the product package.
When  the  User  Account  Control  window  pops  up, 
click the Yes button.
After  installing  WCS-232  v5.0  Setup  Utility, 
Microsoft .NET Framework version 2.0 and Microsoft 
Visual C++ 2005 SP1 Redistributable Package will 
be ready to be installed.
Proceed  with  Microsoft  Visual  C++  2005  SP1 
Redistributable Package installation.
After WCS-232 Setup Utility installation is complete, 
click WCS-232 v5.0 Setup Utility v5 from the Start 
button → SystemBase → WCS-232.
6.4 Remove WCS-232 Setup Utility
Click  WCS-232  Uninstall  from  Start  button  → 
SystemBase → WCS-232
Proceed  with  uninstallation  by  clicking  on  the 
Remove selection.