RadioFrame Networks Inc RFU7 Manuel D’Utilisation
Installing the RadioFrame System
25
1
Choose one:
If the NCU and iSC are… Then…
located in the same
building
building
for an iSCII, connect the NCU to the SRI card on the back of
the iSCII using the provided 1 meter, 50 ohm coaxial cable
with two male BNC connectors:
1. Connect one end of the cable to the 5MHz/1PPS “IN”
the iSCII using the provided 1 meter, 50 ohm coaxial cable
with two male BNC connectors:
1. Connect one end of the cable to the 5MHz/1PPS “IN”
port on the back of the NCU (see the following
illustration).
illustration).
2. Connect the other end of the cable to either BNC
“OUT” port of the SRI slot on the back of the iSC.
for an iSCIII, connect the NCU to the iSCIII using the
provided 1 meter, 50 ohm coaxial cable with two male BNC
connectors:
3. Connect one end of the cable to the 5MHz/1PPS “IN”
provided 1 meter, 50 ohm coaxial cable with two male BNC
connectors:
3. Connect one end of the cable to the 5MHz/1PPS “IN”
port on the back of the NCU (see the following
illustration).
illustration).
4. Connect the other end of the cable to one of the three
5MHz/1PPS “OUT” ports on the back of the iSC. The
port will be determined by Nextel.
port will be determined by Nextel.
located at different
building sites
building sites
the NCU derives its timing from a GPS receiver inside the
NCU, which requires a connection to the building’s GPS
antenna:
1. Insert the GPS antenna cable into the SMB port on the
NCU, which requires a connection to the building’s GPS
antenna:
1. Insert the GPS antenna cable into the SMB port on the
back of the NCU.