20 of 31
them.
2
Pla ce the well- assembled master unit into portable frame onto
the master unit cabinet support. Fix the master unit stably on the
portable frame with M5 screws through the fixing holes on the
ears of the master unit cabinet.
3
Put the tail fiber tray (2U sliding cabinet) (used to put tail fiber)
under the master unit cabinet. Also fix it with M5 screws
through the fixing holes on the ears of the cabinet. Fixing holes
are hole 18 and 20.
4
Then connect cables in turn.
3.2. Installation of Remote Unit
3.2.1 Installation Dimensions
Remote Unit is installed in the way of wall-hanging. External dimensions
a r e (h
× w× d) 368mm× 220mm× 60mm. In installation, drill according to the
distance between the two 8 m m holes of the U- shaped hanging hook attached
with the System.
3.2.2 Space Requirements
Remote Unit should be fixed at a suitable position and height on the wall
for the convenience of maintenance. Ambient temperature should be in the
range of 0 ~40 and relative humidity
≤
85% . Avoid direct sunlight.
3.2.3 Installation Method
Remote Unit cabinet should be hung on wall as shown in figure 3.2-1.