Opticon Sensors Europe BV OPN2005 Manuel D’Utilisation
19
OPN-2005
Specifications Manual
10.4. Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner 3 times (18 times in total), at each 6 face, from a height of
150 cm onto a concrete floor as shown below.
Drop test: Drop the scanner 3 times (18 times in total), at each 6 face, from a height of
150 cm onto a concrete floor as shown below.
Figure 13: Drop Test
10.5. Electrostatic Discharge Immunity
Air discharge:
8 kV Max. (No malfunction)
15 kV Max. (No destruction)
15 kV Max. (No destruction)
Contact discharge:
4 kV Max. (No malfunction) [Discharged from the frame of the
USB connector.]
10 kV Max. (No destruction)
USB connector.]
10 kV Max. (No destruction)
Measurement
environment:
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge
resistance:
resistance:
330 Ω
Capacitor charging:
150 pF
10.6. MTBF
MTBF (Mean Time Between Failures)
30,000 hours (excluding the following parts)
Laser diode :
10,000 hours
Mirror scan unit :
10,000 hours
150 cm