Exciter Configuration    
21 
Exciter Configuration 
Exciters are configured using the AeroScout System Manager or MSE. The 
configuration settings consist of device installation and network definitions
Configuring the Exciter via System Manager 
The configuration procedure involves the following steps: 
1.  Connect all Exciters with a wired Ethernet connection to a dedicated segment. 
2.  Add the Exciters with the AeroScout System Manager, configure their 
parameters and define their IP settings (The preconfigured IP is supplied per 
Exciter).  
If you wish to later change the IP settings (IP, subnet, gateway or ports) you can 
do so by right-clicking on the Exciter and selecting IP Settings. 
3.  Check that the Exciter’s status is OK by right clicking on the Exciter icon and 
selecting Status. Also verify in the status window that the firmware versions 
(DSP and Second Boot) are compatible with the current installed Engine version 
and Exciter hardware version. Consult AeroScout Support regarding the 
appropriate firmware versions. 
4.  Position the Exciter in the site according to site survey recommendations, and 
mount it. 
5.  Align the Exciters’ positions according to the required area coverage. 
6.  If you wish to define the Exciter as an offline Exciter not connected to the 
network, you should approve the above configuration, wait for a confirmation, 
define the Exciter as disconnected from network from the Properties window, 
approve the settings again and disconnect the Exciter from the network. 
For more information please refer to the AeroScout Engine User’s Guide. 
Configuring the Exciter via MSE 
The configuration procedure involves the following steps: 
1.  Open the WCS and select Configure, Chokepoints.