AeroScout ANT4200 Manuel D’Utilisation
AeroScout EX4200 Ultrasound Exciter
Exciter Configuration
21
Exciter Configuration
Exciters are configured using the AeroScout System Manager or MSE. The
configuration settings consist of device installation and network definitions.
configuration settings consist of device installation and network definitions.
Configuring the Exciter via System Manager
The configuration procedure involves the following steps:
1. Connect all Exciters with a wired Ethernet connection to a dedicated segment.
2. Add the Exciters with the AeroScout System Manager, configure their
parameters and define their IP settings (The preconfigured IP is supplied per
Exciter).
Exciter).
If you wish to later change the IP settings (IP, subnet, gateway or ports) you can
do so by right-clicking on the Exciter and selecting IP Settings.
do so by right-clicking on the Exciter and selecting IP Settings.
3. Check that the Exciter’s status is OK by right clicking on the Exciter icon and
selecting Status. Also verify in the status window that the firmware versions
(DSP and Second Boot) are compatible with the current installed Engine version
and Exciter hardware version. Consult AeroScout Support regarding the
appropriate firmware versions.
(DSP and Second Boot) are compatible with the current installed Engine version
and Exciter hardware version. Consult AeroScout Support regarding the
appropriate firmware versions.
4. Position the Exciter in the site according to site survey recommendations, and
mount it.
5. Align the Exciters’ positions according to the required area coverage.
6. If you wish to define the Exciter as an offline Exciter not connected to the
network, you should approve the above configuration, wait for a confirmation,
define the Exciter as disconnected from network from the Properties window,
approve the settings again and disconnect the Exciter from the network.
define the Exciter as disconnected from network from the Properties window,
approve the settings again and disconnect the Exciter from the network.
For more information please refer to the AeroScout Engine User’s Guide.
Configuring the Exciter via MSE
The configuration procedure involves the following steps:
1. Open the WCS and select Configure, Chokepoints.