CipherLab Co. Ltd. 1664 Manuel D’Utilisation

Page de 268
 
 
69
 
Update 
 
Chapter 2
    錯誤!  使用  [常用]  索引標籤將 Heading 1 套用到您想要在此處顯示的文字。
 
2.3.3 ACK/NAK TIMEOUT 
By default, the scanner sends data to the host without waiting for an ACK/NAK response 
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If 
no response within the specified period of time, the scanner will attempt to send the 
same data two more times. If all three attempts fail without any notification, data loss 
will occur. 
 
 
ACK/NAK Time-out 
after … (*0~99)
1)  Read the barcode above to specify the time interval for the scanner to send data and 
wait for a response from the host. 
 
 
 
 
 
 
2)  Read the “
Decimal Value
” barcode on page 251. For example, read “1” and “0” for the 
scanner to automatically shut down after being idle for 1 second.   
3)  Read the “Validate” barcode on the same page to complete this setting. 
 
ACK/NAK Error Beep 
 
Enable Error Beep
 
*Disable Error Beep
Note:  We suggest enabling the error beep so that you will be notified of such data loss 
and have the scanner re-read data. 
2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE 
After the scanner has established a connection as a SPP slave device, you may have it 
read the “Activate Bluetooth
®
 SPP, Master Mode” setup barcode to switch to SPP Master 
Mode. This will result in easy and reliable re-connection, just like connecting with 3610.