• Convert to UPCA: If this parameter is enabled, the UPCE read will be
expanded into UPCA, and the following processing will follow the
parameters configured for UPCA.
parameters configured for UPCA.
• System Number Transmission: If this parameter is enabled, the system
number will be included in the data being transmitted.
• Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
6.6 EAN8
• Convert to EAN13: If this parameter is enabled, the EAN8 read will be
expanded into EAN13, and the following processing will follow the
parameters configured for EAN13.
parameters configured for EAN13.
• Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
6.7 UPCA
• Convert to EAN13: If this parameter is enabled, the UPCA read will be
expanded into EAN13, and the following processing will follow the
parameters configured for EAN13.
parameters configured for EAN13.
• System Number Transmission: If this parameter is enabled, the system
number will be included in the data being transmitted.
• Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
6.8 EAN13
• ISBN / ISSN Conversion: If these parameters are enabled, the scanner will
convert the code read into ISBN or ISSN code if the formats are correct
(EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN).
(EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN).
• Checksum Transmission: If this parameter is enabled, the checksum
character will be included in the data being transmitted.
26
6.9 MSI
• Checksum Verification: Three kinds of checksum calculations can be
implemented into MSI code: Single Modulo 10, Double Modulo 10, or
Modulo 11 & 10 checksum. If the checksum character is incorrect, the
barcode will not be read.
Modulo 11 & 10 checksum. If the checksum character is incorrect, the
barcode will not be read.
• Checksum Transmission: User can control the checksum transmit ion
format by configuring this parameter.
1) Transmitted
2) Last digit not transmitted
3) Last 2 digits not transmitted
2) Last digit not transmitted
3) Last 2 digits not transmitted
• Code Length Qualification: Because of the weak structure of the MSI
code, a partial scan has a high probability of decoding as a valid but shorter
MSI codes (known as short scan). To prevent this kind of undesired
readings, the Code Length settings can help to ensure that the correct code
is read by qualifying the allowable code length. Code length limitations can
be set in 2 ways: Fixed Code Length and Max/Min code length. If the
fixed code length is selected, up to 2 fixed lengths can be specified. And if
max / min code length is selected, the max length and the min length must
be specified, and the scanner will only accept those codes with lengths fall
between max / min length specified.
MSI codes (known as short scan). To prevent this kind of undesired
readings, the Code Length settings can help to ensure that the correct code
is read by qualifying the allowable code length. Code length limitations can
be set in 2 ways: Fixed Code Length and Max/Min code length. If the
fixed code length is selected, up to 2 fixed lengths can be specified. And if
max / min code length is selected, the max length and the min length must
be specified, and the scanner will only accept those codes with lengths fall
between max / min length specified.
6.10 Plessey
• Convert to UK Plessey: If this parameter is enabled, the scanner will
change each occurrence of the character ‘A’ into character ‘X’ in the code.
• Checksum Transmission: If this parameter is enabled, the checksum
characters (two characters) will be transmitted together with data.
6.11 Telepen
• Telepen Output: There are two flavors of encoding formats for Telepen.
One is the original Telepen format and another is AIM Telepen format. User
can choose the desired encoding format for Telepen readings.
can choose the desired encoding format for Telepen readings.