Inside Secure M300 Manuel D’Utilisation

Page de 29
Page 16
GET RESPONSE
Use
This command returns the value contained in the internal buffer of the coupler.
It has to be used to get chip answer when the TRANSMIT command is used with the ISO IN type to retreive the
chip answer.
Prototyping
Command sent :C0h
Command type : ISO out
Host
80h
C0h
00h
00h
P3
Coupler
C0h
Coupler buffer 90h
00h
Parameters
P3: Number of bytes of the coupler response
It has to be less than 35 (23h).
Response : Coupler’s buffer and status words