Send a SET_STATUS command (80h F4h 03h 6Dh 01h & 06h). The coupler
responds (Status words) using 9600  bauds.
State at power on - Is coupler emitting a field when it is powered on ? (please refer to ENABLE and DISABLE
command chapters)
Note : The ACTIVATE AT POWER ON  parameter defines the state of the coupler
when you turn it on. If you turn the coupler on and if 00h is written in the EEPROM
at address 42h , it will be «asleep» until you send an ENABLE_COUPLER
command.
IMPORTANT NOTE : If change in the EEPROM is followed by a reset of the
coupler and if address 42h contains 00h then the coupler will be asleep until you
send an ENABLE command.
Coupler's INPUTS and OUTPUTS
Please refer to chapter 1 for connection.
EEPROM free area
User can use EEPROM bytes from 70h to 7Dh to write some data.
Couplers - Reference Manuel V1.3
Name
Address
State
Hex. value
Available on...
Enable
01h
Disable
00h
All reader
42h
State at 
power on
Reader
Input / Output
I/O address
Command to 
use
Value
OUT1
05h - Bit 1
Set Status
OUT 2
05h - bit 2
Set Status
IN 1
07h - bit 0
Read Status
M22xH
OUT
05h - bit 2
Set Status
M302H
OUT
06h - bit 4
Set Status
Byte value & color
04h : Red
08h : Orange
0Ch : Green
Bit at 0 : low level
Bit at 1 : High level
M21xH
Set Status
05h
LED
ACCESSO