Inside Secure M300 Manuel D’Utilisation
Page 23
ENABLE COUPLER
Use
This command restores a normal coupler running, with RF emission.
This command can only be used after a DISABLE_COUPLER command or if the coupler is desactivated after
power on.
power on.
Prototyping
Command sent : AEh
Command type : ISO none
Parameters
Response : Status words
The coupler will respond «Instruction not recognized» (6Dh 00h) if already activated.
Important note : You have to send the ENABLE_COUPLER command in a window
of 16ms. To be sure that your command will be received, send it twice. The time
between the sending of the 2 commands has to be less than 10 ms.
This is automatically done when using MX.Enable method (ActiveX component).
of 16ms. To be sure that your command will be received, send it twice. The time
between the sending of the 2 commands has to be less than 10 ms.
This is automatically done when using MX.Enable method (ActiveX component).
Couplers - Reference Manuel V1.3
Host
80h
AEh
DAh
BCh
00h
Coupler
3Bh
00h