Inside Secure M300 Manuel D’Utilisation

Page de 29
Page 23
ENABLE COUPLER
Use
This command restores a normal coupler running, with RF emission.
This command can only be used after a DISABLE_COUPLER command or if the coupler is desactivated after
power on.
Prototyping
Command sent : AEh
Command type : ISO none
Parameters
Response : Status words
The coupler will respond «Instruction not recognized» (6Dh 00h) if already activated.
Important note : You have to send the ENABLE_COUPLER command in a window
of 16ms. To be sure that your command will be received, send it twice. The time
between the sending of the 2 commands has to be less than 10 ms.
This is automatically done when using MX.Enable method (ActiveX component).
Couplers - Reference Manuel V1.3
Host
80h
AEh
DAh
BCh
00h
Coupler
3Bh
00h