Shenzhen Kirisun Communications Co. Ltd. TR85001 Manuel D’Utilisation

Page de 31
TR850 DMR Repeater                                                                              Instruction Manual 
16 
 
pop up a dialog box, shows
“ Write data successfully”. 
When you try to write data, tick the option “Exit after finish”, when finish writing data, the dialog box 
will exit automatically. If not tick this option, users have to press 
“Exit” manually to close the box. 
Notes 
(1)  When  try  to  read  data,  have  to  check  the  network,  make  sure  the  program  menu  tick  the 
“Network”  option,  make  sure  the  IP  on  the  tools  bar  is  the  IP  of  the  repeater  you  are  going  to 
program. 
(2) When the connectivity is successful, the top of the dialog box of “Reading data” and status bar 
will show “Network is OK”, otherwise will be shown “Network XX”.   
Upgrade  software:  the  main  function  is  to  download  different  function  modules  from  PC  to  the 
repeater, then set the main parameters on them. 
Under  the  “Program”  menu,  find  “Program  Download”,  then  you  can  upgrade.  But  before 
upgrading,  you  should  select  the  path  of  the  update  package.  If  is  a  standard  update  package, 
after select the path, each update file’s paths will be auto filled.   
  Upgrade Boot Loader 
(1)Before upgrading, 
repeater should be power off, boot mode select 0101, select “Download 
boot loader” and find the correct serial port between PC and repeater. If necessary, select the boot 
loader file and uboot file.   
(2)
Press “Download” button, then a upgrade dialog box pops up, select “Yes”. 
(3)
When the control program shows “Wait for boot me……” the interface power on (Note: if the